OPERATING AND INSTALLATION INSTRUCTIONS LBE 250A / LBE 500A
PAGE 42
USER
GENERAL
SPECIALIS
T PERSONNEL
Kupplungsnabe und Kugellager
Kugellager
Add some cleaning agent into the vessel and fill it up with warm water until the
lamellae are completely covered.
Only use biologically-based cleaning agents!
Observe the safety instructions!
The coupling hub and the ball bearing must not be covered by the
water.
Depending on how dirty the lamellae are, it is advisable to keep the rotor lamel-
lae in the detergent solution between 3 and 6 hours. Afterwards, rinse the rotor
lamellae with warm water.
Ansicht von oben
Detail Z
Z
Netzstecker
Abdeckung
Schrauben
Schrauben
UVC-Röhre
Verbindungsstecker
Schrauben
Deckel
Gehäusefront
Schrauben
Innendeckel
Rotor
richtige Position
Zulaufschlauch
Osmoseeinheit
Wasserwanne
UVC-Röhre
Replacing the osmosis membrane
When you carry out this workstep, water may leak from the osmosis
unit!
Two black plastic tubes are connected to the osmosis unit. One tube (supply
tube) leads from the water valve to the osmosis unit, and one tube leads from
the osmosis unit to the tank inlet.
First the supply tube from the osmosis unit must be disconnected. For this pur-
pose, press the clamp ring at the valve connector backwards and at the same
time remove the tube.
The LBE 500A type contains two osmosis units. You must always re-
place both osmosis membranes at the same time!
Then unscrew the cover from the osmosis unit and draw the osmosis mem-
brane out of the housing.
After having replaced the osmosis membrane, screw on the cover again and in-
sert the tubes into the valve connectors.
Exert tensile force to ensure that the tubes are firmly fit and that the
connection is tight!
Ansicht von oben
Detail Z
Z
Netzstecker
Abdeckung
Schrauben
Schrauben
UVC-Röhre
Verbindungsstecker
Schrauben
Deckel
Gehäusefront
Schrauben
Innendeckel
Rotor
richtige Position
Zulaufschlauch
Osmoseeinheit
Wasserwanne
UVC-Röhre
Clean the water tank of the air humidifier with a damp cloth.
Supply tube
Osmosis unit
Water tank
UVC tube