background image

Содержание 758.144171

Страница 1: ...r s manual Stock No 42 14417 IVlodei No 758 144171 FOR YOUR READ ALL INSTRUCTIONS CAREFULLY J QUIETCOMFORT WHOLE HOUSE HUMiDiFiER t4 Gallon Output tnnovative Twin Fan Technology o Operating instructions Parts List Sears Roebuck and Co Hoffman Estates tL 60179 U S A Part No SP6553 Printed in Canada ...

Страница 2: ... the electric cord under rugs near heat registers radiators stoves or heaters 3 Always unplug the humidifier before moving it before cbaning or whenever the humidifier is not in service INSTRUCTIONS Keep the humidifier clean Do not put foreign objects inside the humidifier Never use your humidifier while any part is missing or damaged in any manner To reduce the risk of electrical hazard or damage...

Страница 3: ...rs Capacity of Bottles Sq Ft Coverage Fan Speeds Filters Independent Bottle Gauges Fill Indicator 42 14417 14 2 3 8 Gallons Each 2900 3 Set of 4 42 14911 Yes Yes dndependent Bottle Automatic Shutoff Automatic Humidistat Controls CUL Listed Volts Hertz Amps Watts Yes Yes Rotary Yes 120 A C 80 2 88 165 Based on an area with average insulation and an 8 foot ceiling height ANSI AHAM HU 1 1997 SEC 8 1 ...

Страница 4: ...r Assembly Your new Sears Kenmore humidifier iscorn a from inside your humidifier and follow the pletely assembled for you to use Remove instructions of this owner s manual for prop the bag pack containing two plastic caster er usage The packaging material is located pads from top of humidifier and retain for under the fan assembly Remove the pack future use if require See step 1 below for aging m...

Страница 5: ...ok Up Locate nearest 120V A C wall socket in the location desired preferably on inside wall With the humidifier in the desired location route the electrical cord safely so no one wilt trip or upset the humidifier Hug in the electrical cord IWARNtNG To reduce the risk of fire m or shock hazard humidifier should be I plugged directJy into a t20V A C out m let De not useextens en cords m To reduce th...

Страница 6: ...hold the bottle upright over a sink Press up on valve cap plunger for about one second to let out a little water Release the plunger Listen for air bubbles Look for leaks around the E Z Fill Side Cap If you hear air bubbles or see leaks retighten the E Z Fill Side Cap and repeat steps 1 4 Vipe off excess water from the bottle _osition the water bottle back into the unit by irasping the water bottl...

Страница 7: ... When the unit is energized the cen ter area of the control panel containing the gauges and fill indicators will illuminate red to depict the operation mode The right bot tle as viewed from the front of the humidifier wil always empty first As it empties the number of red bars will decrease When it is totally empty the Fill Indicator immediately beside the bars will Illuminate NOTE The humidifier ...

Страница 8: ...ondensation no longer forms Step 4 If humidifier stops running and BOTH Fil indicators are not on the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions The chart below shows recommended indoor humidity levels The figure below shows approximate relative humidity per centages which correspond to the various settings of the Humidity Control When O...

Страница 9: ...d moving the humidifier to an area where floor coverings are not suscepti ble to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat sur face The filter housings are now acces sible 3 Lift filter housing out of cabinet and place where you may work on them com...

Страница 10: ...t and back orientation To position the filter housings correctly Front of Humidifier Be sure that the spring tabs of filter housings are towards front of cabi net Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cab inet f Position fan assembly onto the cabi net Make sure the fan venturi low est cylinder section below the fan is placed i...

Страница 11: ...tart after housing is removed 11 Step 2 To Remove Parts a Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat sur face The filter housings are now accessible b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor coverings are not sus...

Страница 12: ...ntenance instructions at end of humidification season 2 Remove and throw away filters 3 Let humidifier dry completely before storing Do not store with water inside cabinet or water bottles 4 Store in coo dry location 5 Install new filters in clean humidifier before next season begins 6 Bi Weekly is also recommended if you do not plan to run the humidifier for one week or more Disinfecting Humidifi...

Страница 13: ...ater at the rear of the cabinet This is normal A small amount of water remains in the cabinet after Fill Lights come on Position float retainer in Manual Dryout position to completely dry out See page 7 Check E ZoFill Side Caps and valve assembly caps to ensure tightness Check for leak in water bottles Ensure gaskets for E Z Fill Side Caps are in place Check orientation of bottles Reposition so th...

Страница 14: ...J 27 I _ f i 24 _ 23 27 t w S 26 33 23 ...

Страница 15: ... 828515 23 830560 1 24 42 14911 25 828197 26 828534 27 828115 1 28 822406_1 29 828197 30 828858 31 816069 5 32 816069_6 33 STD600805 34 824101 I 35 828200 36 828745 37 828920 SP6553 Rail Kick Screw Pan Hd Ty AB 10 x 3 4 Caster Twin Wheel Support Filter Lower 1 Fitter Evaporative Support Upper Filter Support Motor Motor includes mounting hardware Fan Support Upper Filter Cord w Plug Screw Pan Hd Ty...

Страница 16: ...ome For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacie...

Отзывы: