OPERATING AND INSTALLATION INSTRUCTIONS LBE 250A / LBE 500A
PAGE 19
USER
GENERAL
SPECIALIS
T PERSONNEL
9.4.4 OPERATING TIME OF THE OSMOSIS FILTER
Over time, the osmosis membrane is blocked by small particles, impeding the passage of the pure water. For reasons of operational
safety and for hygienic reasons, the osmosis filters should therefore be replaced when its maximally recommended operating time is
reached, however, once every 2 years at the latest.
In the course of the osmosis filter replacement, the rotation lamellae and the humidifier tank should also be cleaned.
Maintenance instructions
(see Chapter 15.2)
9.4.5 OPERATING TIME OF THE AIR HUMIDIFIER
The total time during which the air humidification unit has carried out active humidification is counted in hours and shown in days.
The time can be reset if required, for instance if more extensive repair and maintenance work is carried out.