CALIBRATION OF THE CLEANING SYSTEM
48
Select «Service > PH cleaning system calibration > Y» on the menu. Rotate the joystick
to adjust the position of the nozzle along the Y axis so that the nozzle end is exactly
above the template pointer. Press the joystick.
4.
Open the menu «Service > PH cleaning system calibration > test» and choose a test
without heating and pushing; the printhead moves to the position above the template.
Check the nozzle position relative to the template pointer. If the positions do not match,
repeat the calibration; otherwise, replace the template for the silicone cleaner and continue
using Designer XL.
Additionally, you can perform a test with heating and punching the filament; in this case,
the PH starts the filament loading algorithm at the point of being above the cleaner. If the
system is calibrated correctly, thin and even filament comes out from under the cleaner.