CALIBRATION OF THE CLEANING SYSTEM
47
Follow step-by-step instructions to complete the calibration:
Replace a silicone cleaner for the printed cleaner calibration template.
Select «Service > PH cleaning system calibration > X» on the menu.
The printhead moves to the adjustment position and stops above the template. Rotate
the joystick to adjust the position of the nozzle along the X axis so that the nozzle end is
exactly above the template pointer. Press the joystick.
1.
2.
3.
Before calibrating, make sure that the container is removed and wait until the nozzle cools
down to a temperature of no more than 50 ºC: it’s approximately 10 or 15 minutes after the
latest heating.