phyCORE-P8xC51Mx2
50
PHYTEC MMesstechnikGmbH 2005 L-602e_3
Figure 17:
Connecting the Supply Voltage at X1
Caution:
When using the 5 V supply, the following jumper settings are not
allowed:
Jumper
Setting
Description
1 + 2
3,3 V as main supply voltage for the
phyCORE-P8xC51Mx2 (if 5 V version of the
module is used)
2 + 3
5 V as main supply voltage for the
phyCORE-P8xC51Mx2 (if 3.3 V version of the
module is used)
JP9
open
phyCORE-P8xC51Mx2 not connected to
main supply voltage
Table 21:
JP9 Improper Jumper Settings for the Main Supply Voltage
Correct setting of Jumper JP9 depends on the available version of the
phyCORE-P8xC51Mx2 mounted on the phyCORE Development
Board. Depending whether the 5 V or 3.3 V version is used, JP9 must
be set accordingly. Incorrect jumper setting could destroy the module.
If Jumper JP9 is open, no main power supply is connected to the
phyCORE-P8xC51Mx2. This jumper setting should therefore never
be used.
+5 VDC
GND
≥
500 mA
Center Hole
1,3 mm
3,5 mm
--
+
Polarity: