The phyCORE-P8xC51Mx2 on the Development Board LD 5V
PHYTEC Messtechnik GmbH 2005 L-602e_3
49
14.3
Functional Components on the phyCORE
Development Board LD 5V
This section describes the functional components of the phyCORE
Development Board LD 5V supported by the phyCORE-P8xC51Mx2
and appropriate jumper settings to activate these components.
Depending on the specific configuration of the
phyCORE-P8xC51Mx2 module, alternative jumper settings can be
used. These jumper settings are different from the factory default
settings as shown in Figure 16 and enable alternative or additional
functions on the phyCORE Development Board LD 5V depending on
user needs.
14.3.1
Power Supply at X1
Caution:
Do not use a laboratory adapter to supply power to the Development
Board! Power spikes during power-on could destroy the phyCORE
module mounted on the Development Board! Do not change modules
or jumper settings while the Development Board is supplied with
power!
Permissible input voltage: +5 VDC
±
5% regulated.
The required current load capacity of the power supply depends on
the specific configuration of the phyCORE-P8xC51Mx2 mounted on
the Development Board as well as whether an optional expansion
board is connected to the Development Board. An adapter with a
minimum supply of 500 mA is recommended
Jumper
Setting
Description
JP9
2 + 3
5 V main supply voltage to the
phyCORE-P8xC51Mx2 (5 V version of the module)
JP9
1 + 2
3.3 V main supply voltage to the
phyCORE-P8xC51Mx2 (3.3 V version of the module)
Table 20:
JP9 Configuration of the Main Supply Voltage VCCI
1
:
If the phyCORE-P8xC51Mx2 is purchased in a Rapid Development Kit, an appropriate 5V
power adapter is included.
Содержание phyCORE-P8xC51Mx2
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE P8xC51Mx2 Hardware Manual Edition April 2005...
Страница 22: ...phyCORE P8xC51Mx2 14 PHYTEC MMesstechnikGmbH 2005 L 602e_3 Figure 7 Location of the Jumpers Bottom View...
Страница 46: ...phyCORE P8xC51Mx2 38 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 50: ...phyCORE P8xC51Mx2 42 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 82: ...Published by PHYTEC Messtechnik GmbH 2005 Ordering No L 602e_3 Printed in Germany...