Hints for Handling the Module
PHYTEC Messtechnik GmbH 2005 L-602e_3
41
13
Hints for Handling the Module
If changing controllers, please ensure that appropriate PLCC
extraction tools are used and that the socket and all components
remain free from intrusive damage.
Removal of the standard quartz or oscillator is not advisable given the
compact nature of the module. Should this nonetheless be necessary,
please ensure that the board, as well as surrounding components and
sockets, remain undamaged while desoldering. Overheating the board
can cause the solder pads to loosen, rendering the module inoperable.
Carefully heat neighboring connections in pairs. After a few
alternations, components can be removed with the solder-iron tip.
Alternatively, a hot air gun can be used to heat and loosen the bonds.