1 .   P R O D U C T

  D E S C R I P T I O N  

I n t r o d u c t i o n  

 

Introduction 

The PoLRE switch is a Power over Long Reach Ethernet switch. Unlike traditional Ethernet switches, the 

PoLRE switch has a reach of up to 1200 feet (365 meters) and is capable of delivering power and signaling 

over a single pair CAT3 cable. A Phylink adapter is installed at each IP endpoint, carrying the power and 

signaling to the connected IEEE 802.3af compliant end devices. 
The default PoLRE configuration supports IP phones and provides a plug and play solution for replacing a 

legacy voice network using the existing network cabling plan. Up to 48 IP phones can be powered from a 

single PoLRE switch. 

 

The PoLRE switch is a 1U, 19", rackmount 24/48-port Power over Ethernet (PoE) switch. Its upstream 

ports connect to the IP PBX, router or data switch over a GbE copper connection. Unlike the typical PoE 

switch, however, its downstream ports connect to either one or two 25-pair RJ21 connectors and run over 

voice-grade CAT3 cable extending up to 1200 feet (365 meters). 
This permits the use of a legacy 2-wire telephony infrastructure to carry voice, data and signals between 

the upstream switch or IP PBX to all IP endpoints in the network. Phylink adapters at the IP endpoints are 

like media converters that switch from the single CAT3 pair to a standard RJ45 Ethernet PoE connection 

for connectivity and power to the attached IP device. 

Important: Devices attached at the IP endpoints must be IEEE 802.3af compliant. 

IP telephony (IPT) systems deploying the PoLRE switch provide both the robustness of traditional 

telephony systems and the easy mobility of IP devices. Multiple PoLRE switches can also be daisy-chained 

together to operate in Powershare mode if one switch’s power supply should fail. 

 

Содержание PoLRE

Страница 1: ...PoLRE Switch Hardware Installation Guide Release 1 2...

Страница 2: ...kes no warranties regarding the content of this document Phybridge is not responsible for any loss or damages arising from the use or misuse of this document The information contained in this document...

Страница 3: ...umber and password ready when calling Returning a PoLRE Switch If you must return a PoLRE switch Phylink adapter or accessory component to Phybridge Inc ensure that all items are adequately protected...

Страница 4: ...netic field or electrostatic charge Damage to system components could result Warnings A warning contains an instruction that the reader must follow in order to prevent electrical shock death or seriou...

Страница 5: ...link Ports 6 GbE Port Pinout 7 Downlink Ports 7 Downlink Port Pinout 7 Ports 1 to 24 8 Ports 25 to 48 8 Out of band Management Port 8 Out of band Management Port Pinout 9 Console Port 9 Reset Button 1...

Страница 6: ...ith IP Endpoint Devices 23 Connecting a PC Behind the IP Phone 24 Connecting to the 2 wire Network Infrastructure 24 Connecting to the Console 26 Connecting to the IP PBX 26 GbE Port Connection 27 Gbi...

Страница 7: ...odels 24 Port and 48 Port page 3 PoLRE Switch Rear View Models 24 Port and 48 Port page 4 Power Supply Unit page 5 Uplink Ports page 6 Downlink Ports page 7 Out of band Management Port page 8 Console...

Страница 8: ...he IP PBX router or data switch over a GbE copper connection Unlike the typical PoE switch however its downstream ports connect to either one or two 25 pair RJ21 connectors and run over voice grade CA...

Страница 9: ...1 P RO DUCT DES CRIP TION P oLRE S wi tc h Har d war e Descri pt i on 3 PoLRE Switch Hardware Description PoLRE Switch Front View Models 24 Port and 48 Port Model 48 Port Model 24 Port...

Страница 10: ...switch indicates the generic model number 24 Ports or 48 Ports The product serial number as well as the switch specific model number are on a label affixed to the left side of the rear panel You may...

Страница 11: ...onnector at the rear Autosensing 100 240VAC 50 60 Hz 2 male DC connectors In Out at the rear of the unit for Powershare 54VDC nominal 42VDC to 58VDC tolerance Power output 500W max at 100VAC 1000W max...

Страница 12: ...tion upload download status monitoring and management system interactions Speed 1 GbE full duplex Number of ports Total of 2 Cable required copper CAT 5e or better CAUTION Do not connect both ports to...

Страница 13: ...T Rx T Rx Downlink Ports Provide downlink connections Ethernet with PoE Speed 10 Mb s full duplex Number of ports Model 24 Port 1 RJ21 male telco connector standard 24 pairs used Model 48 Port 2 RJ21...

Страница 14: ...25 to 48 PIN Number 1 2 3 4 5 6 7 8 18 19 20 21 22 23 24 25 Port Number TR 25 TR 26 TR 27 TR 28 TR 29 TR 30 TR 31 TR 32 TR 42 TR 43 TR 44 TR 45 TR 46 TR 47 TR 48 X PIN Number 26 27 28 29 30 31 32 33...

Страница 15: ...t Pin Function 1 TX 2 TX 3 RX 4 5 Bob Smith Termination 6 Rx 7 8 Bob Smith Termination Console Port 1 RJ45 UART port labeled Console Dedicated port for management of the PoLRE switch via a console ter...

Страница 16: ...abeled Reset for manually restarting the PoLRE switch Located on the front panel of the PoLRE switch immediately to the right of the power supply unit Use a paper clip or something similar to press th...

Страница 17: ...rtup then turns off Lights solid to indicate a problem with the PSU FAULT red Flashes once during startup then turns off Lights solid to indicate a PoLRE switch software or hardware failure Contact Ph...

Страница 18: ...56 Weight 22 g 0 78 oz Network Infrastructure Connector RJ11 port Connects to the single CAT3 pair on the legacy infrastructure side Ethernet Connector RJ45 port Provides connectivity and power to the...

Страница 19: ...t 1 console cable 1 power cord Other PoLRE components are packaged separately for installation in the field Verify that you have received all of the items you ordered Phylink adapters The number of ad...

Страница 20: ...f supporting the size and weight of the PoLRE switch its installable components and cabling Refer to PoLRE Switch Dimensions page 4 Ensure that you have enough rack space for all equipment Shelves and...

Страница 21: ...he CONSOLE port provided with the product package Standard CAT 5 or CAT 6 Ethernet LAN cable for the MGMT port user supplied DC cables for multiple switch configuration in Powershare mode optional Scr...

Страница 22: ...16 2 U NP AC KI NG Before Y ou I ns tall...

Страница 23: ...acing Legacy Devices with IP Endpoint Devices page 23 Connecting a PC Behind the IP Phone page 24 Connecting to the 2 wire Network Infrastructure page 24 Connecting to the Console page 26 Connecting t...

Страница 24: ...is CAUTION When upgrading a telephony environment make sure you have removed all of the old analog digital phones and fax machines before you apply power CAUTION To ensure trouble free synchronization...

Страница 25: ...ist einer der wichtigsten Erdungsklemme die dauerhaft auf die Erde angeschlossen werden muss Seul un sp cialiste doit avoir acc s l appareil Cette unit peut avoir plus d une entr e d alimentation Pour...

Страница 26: ...be used on the components of the PoLRE switch or applied to the interior of the switch Care of Replaceable Components CAUTION Handle replacement components with care Do not drop them Do not spill liqu...

Страница 27: ...ole cable See Connecting to the Console page 26 7 Connect the uplink cable from a Gigabit port to the IP PBX or network switch See Connecting to the IP PBX page 26 CAUTION Do not connect both ports to...

Страница 28: ...nit This handle is intended for removing and replacing the PSU only 3 Slide the PoLRE switch into the rack along its horizontal supports or suspend the switch in place using another means of support s...

Страница 29: ...ratings should be used when addressing this concern For reliability reasons the PoLRE switch should be powered from a dedicated mains outlet Reliable Earthing Reliable earthing of rack mounted equipm...

Страница 30: ...establish VLANs to ensure Quality of Service For more information on how to set up VLANs see the PoLRE Switch User Guide Note Data speeds are 10 Mb s Full Duplex Connecting to the 2 wire Network Infr...

Страница 31: ...to a downlink port Tip If you are installing only one RJ21 telco cable on a model 48 Port either downlink port can be used However for easier reference to port numbering use the connector on the left...

Страница 32: ...uter must be running at 115 200 baud with 8 data bits no parity and 1 stop bit Connecting to the IP PBX You can connect the PoLRE switch to the uplink network switch IP PBX or router in two ways GbE P...

Страница 33: ...P RSTP is enabled For more information see the PoLRE Switch User Guide as well as the 3300 MCD Resiliency Guidelines Note Both ports can be used If only one connection will be installed use the port l...

Страница 34: ...pulling it down over the black cap When open it can be used as a handle for inserting or removing the SFP module 3 Determine which Gbic port will be installed with this SFP module For the upper port...

Страница 35: ...the SFP module 2 Unlock the SPF module If the SFP module is in port Gbic 1 flip the handle down to unlock the module If the SFP module is in port Gbic 2 flip the handle up 3 If required remove the pr...

Страница 36: ...Remove the black protective cap from the SFP transceiver module WARNING DO NOT look into the SFP connector when it is installed in a Gbic port as the laser beam can cause serious eye injury 2 Connect...

Страница 37: ...his requires multiple PoLRE switches installed in a standard 19 equipment rack For details refer to Daisy chaining PoLRE Switches for Powershare page 32 AC Connection To connect the PoLRE switch to an...

Страница 38: ...nected in a ring using the DC In Out connectors at the rear of the switch If a power fault occurs on any switch in the ring the others are able to share the load and the affected switch continues to f...

Страница 39: ...uipment rack with no more than 1U space between any two switches Refer to Installing the Switch in a Rack page 21 Note You can daisy chain the switches together while they are up and running or power...

Страница 40: ...switch press the hairpin clip at the top of the DC cable and pull the cable out Replacing the Power Supply Unit If a power supply unit fails you must replace it with a new power supply unit as soon a...

Страница 41: ...with the handle on the right side 2 Lift the new power supply unit by its handle and slide it straight into the PSU housing on the left side of the PoLRE switch 3 Push firmly on the power supply unit...

Страница 42: ...apter Model 24 Port 1 RJ21 male telco connector standard 24 pairs used Model 48 Port 2 RJ21 male telco connectors standard 48 pairs used Maximum distance 1200 365m CAT3 UTP cable 24 AWG Speed 10Mb s f...

Страница 43: ...D Weight 22 g 0 78 oz Enclosure ABS AF 312B Mounting Inline between the CAT5e cable to IP endpoint and the CAT3 cable to RJ11 jack Interfaces PoLRE side 1 RJ11 port CAT3 unshielded single twisted pair...

Страница 44: ...5 CO MP LIANCE AND ENVIRO NMENTAL INFO RMATIO N 38 5 Compliance and Environmental information All the compliance and environmental information is available on our website www phybridge com...

Страница 45: ...ernet Protocol IPT IP Telephony LED Light Emitting Diode NMS Network Management System OAM P Operations Administration Maintenance and Provisioning PoE Power over Ethernet PoLRE Power over Long Reach...

Страница 46: ...40 6 ACRO NYMS...

Страница 47: ...itch 5 ESD procedure 18 Ethernet port PoLRE switch 12 FAULT LED 11 fiber optic cable 29 front panel 3 GbE port connection 26 Gbic port connection 26 ground lug 18 installation 17 2 wire network connec...

Страница 48: ...cators 11 Powershare 31 product numbers Phylink adapter 11 PoLRE switch 4 product package 13 rackmount installation 20 safety warnings 22 rear panel 4 redundancy Powershare 31 removal SFP module 28 re...

Страница 49: ...2115 South Service Road West Oakville ON L6L 5W2 Canada Tel 1 888 901 3633 Fax 1 866 252 9148 Web www phybridge com...

Отзывы: