![Phoenix Contact 1624130 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/phoenix-contact/1624130/1624130_user-manual_1551407055.webp)
Signal contacts and charging sequences
107068_en_06
PHOENIX CONTACT
55 / 74
7. Switch-off
C2
Vehicle reduces charging current in accordance with the battery management sys
-
tem (BMS)
C2
Charging station reduces charging current down to a charging current of <1 A
C2
Vehicle cancels charging enabled (vehicle no longer in the “Ready to charge” state)
C2
Vehicle opens its DC contactors if charging current <1 A
C2
Charging station discharges DC intermediate circuit
C2
Charging station switches to the “EVSE_NotReady” state
B2
Vehicle switches to status B2 by opening switch S2
B2
Vehicle unlocks vehicle charging connector in the vehicle charging inlet if voltage
between DC+ and DC- <60 V
B2
Vehicle stops digital communication with the charging station
B1
Three to five seconds after digital communication is stopped, the charging station
switches the PWM off
8. Disconnect vehicle
from charging station
A1
Vehicle charging connector disconnected from vehicle
1
Vehicle status in accordance with IEC 61851-1
Table 5
-
5
Phases of the DC charging sequence in a Combined Charging System (CCS)
Phase
Status
1
Status change and actions
For other sequences required in special situations (e.g., emergency switch-off), refer to
standards IEC 61851
-
23, Annex CC, and DIN SPEC 70121.