![Phoenix Contact 1624130 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/phoenix-contact/1624130/1624130_user-manual_1551407023.webp)
Description of the EV
-
PLCC
-
AC1
-
DC1
107068_en_06
PHOENIX CONTACT
23 / 74
3.7
Digital outputs
16 digital outputs in accordance with IEC 61131-2 are available.
Figure 3
-
5
Terminal point assignment of the output connector
A 24 V DC power supply is required for using the digital outputs (see
).
Table 3
-
4
Terminal point assignment of the output connector
Terminal point
Assignment Description
1.1 and 2.1
+24 V
24 V supply voltage U
S
1.2 ... 1.4 and 2.2 ... 2.4 PGND
Reference potential
1.5
Q1
Output 1
1.6
Q2
Output 2
1.7
Q3
Output 3
1.8
Q4
Output 4
1.9
Q5
Output 5
1.10
Q6
Output 6
1.11
Q7
Output 7
1.12
Q8
Output 8
2.5
Q9
Output 9
2.6
Q10
Output 10
2.7
Q11
Output 11
2.8
Q12
Output 12
2.9
Q13
Output 13
EV
CH
A
R
GE
CON
T
RO
L
X2.2
X3
X4
RS232
RS485
RS485
X5
COM
X7
X9
SD CARD
Digital OUT
X11
Digital IN
X10
SIM
ANT
UL
UM
US
FR
FF
E
RS232-1
RS232-2
RS485-1
RS485-2
CAN
GSM St.
GSM TR.
Error
Plug
Charge
PLC
Error
Plug
Charge
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
X11