Description of the EV
-
PLCC
-
AC1
-
DC1
107068_en_06
PHOENIX CONTACT
17 / 74
E
Red
Error
Off
No short circuit/overload at one output/several outputs
On
Short circuit/overload has occurred at one or more outputs 1 to 16.
COM: communication interfaces
RS232-1
Yellow
Communication via RS-232 interface 1
Off
No data transmission
Flashing Data transmission active
RS232-2
Yellow
Communication via RS-232 interface 2
Off
No data transmission
Flashing Data transmission active
RS485-1
Yellow
Communication via RS-485 interface 1
Off
No data transmission
Flashing Data transmission active
RS485-2
Yellow
Communication via RS-485 interface 2
Off
No data transmission
Flashing Data transmission active
CAN
Yellow
Communication via CAN bus interface
Off
No data transmission
Flashing Data transmission active
GSM St.
Yellow
GSM status
Off
The integrated cellular modem is not switched on.
Flashing The integrated cellular modem is registered in the GSM network.
Flashing
rapidly
Network search
The integrated cellular modem is not registered in the GSM network.
On
The device is logged into the GSM network.
GSM TR
Yellow
GSM/GPRS communication via integrated cellular modem
Off
No GSM/GPRS data transmission
On
GSM/GPRS data transmission active
Table 3
-
2
Diagnostics and status indicators of the controller
Des.
Color
Status