EV
-
PLCC
-
AC1
-
DC1
46 / 74
PHOENIX CONTACT
107068_en_06
5 Signal contacts and charging sequences
5.1
AC charging
The sequence of processes involved in AC charging is based on standard IEC 61851
-
1,
Annex A.
5.1.1
Proximity Plug (PP)
The Proximity Plug is used to detect a charging connector in the charging station, and to de
-
termine its current carrying capacity.
Figure 5
-
1
Proximity Plug (PP) circuit
The current carrying capacity is identified in accordance with IEC 61851-1 via resistor Rc.
The device measures the resistance value via the PP (Proximity Plug) signal and deter
-
mines the current carrying capacity of the connected charging cable.
The coding of the permissible current for the resistance value is defined in IEC 61851-1.
The PP signal is only relevant for charging stations with an infrastructure charging socket
).
The PP signal has no relevance for charging stations with a vehicle connector (connection
case C, see
) and is ignored.
Table 5
-
1
Coding of the permissible current for the resistance value in accordance
with
IEC 61851-1
Rc resistance value in
accordance with the
standard
Tolerance range
Resulting current carry
-
ing capacity
–
<75 Ω
Error
100 Ω
75 Ω ... 150 Ω
63 (70) A
220 Ω
150 Ω ... 330 Ω
32 A
680 Ω
330 Ω ... 1000 Ω
20 A
1500 Ω
1000 Ω ... 2200 Ω
13 A
–
>2200 Ω
0 A
V+
Rc
Pro
ximi
t
y
P
l
ug
P
E
Содержание 1624130