![Phoenix Contact 1624130 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/phoenix-contact/1624130/1624130_user-manual_1551407031.webp)
Description of the EV
-
PLCC
-
AC1
-
DC1
107068_en_06
PHOENIX CONTACT
31 / 74
Figure 3
-
16
Connection example 2: GB/T charging connector
3.8.5
Cellular modem
An integrated cellular modem is available for OCPP communication with a backend system.
An external antenna must be connected to use the cellular modem, see
and connecting the antenna” on page 42
.
The PC Worx software includes function blocks for OCPP communication with the backend
via the cellular modem. They can be downloaded as a StartUpPackage in the product
download area on the e-shop.
X3
X4
RS232
RS485
CAN
X5
COM
X6
X7
AC Charging
DC Charging
X8
X9
SD
ard
C
Digital OUT
X11
Digital IN
X10
UL
UM
US
FR
FF
E
RS232-1
RS232-2
RS485-1
RS485-2
CAN
GSM St.
GSM TR
Error
Plug
Charge
PLC
Error
Plug
Charge
EV-PLCC-AC1-DC1
Ord. No. 1624130
CRTL
COM
EV
DC
AC
X3
X4
X5
X6
X7
X8
X9
X10
X11
1 2 3 4 5
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7
1 2
1 2
1.1
1.2
1.3
1.4
1.
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
1.4 ... 2.4
1.5...2.12
X10
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
1.5 or 2..12
X11
POWER
OUT
IN
U, I
FM
POWER
OUT
IN
U, I
FM
POWER
OUT
IN
U, I
FM
A1
0V
12V
0V
13
21
14
22
Locking relais
A1
0V
12V
0V
13
21
14
22
Unlocking relais
CC1
Lock det
C
AN-L (S-)
C
AN-H (S+)
T
emp1 +
T
emp -
AC/DC
DC-
DC+
Temp2 + (not usable)
+12V
0V
+24V
0V
Lock detection -
Lock +
Lock -
12V
6V
4V
MINI MCR-2-UI-REL-PT MINI MCR-2-UI-REL-PT
MINI MCR-2-UI-REL-PT
Spo
w
er+
Spo
w
er-
A+
A-
PE
The antenna is not included in the scope of delivery of the charging controller.
Please refer to the ordering data in
.
Содержание 1624130
Страница 1: ...User manual Installing and operating the EV PLCC AC1 DC1 controller...
Страница 71: ...EV PLCC AC1 DC1 72 74 PHOENIX CONTACT 107068_en_06...
Страница 74: ......