PDS-60 Product Guide
5
Maximum data cable lengths are 100 m (328 ft) between Ethernet devices without a
repeater.
Electrical Configuration Guidelines
The number of luminaires that each PDS-60 unit can support depends on the power
requirements of the specific luminaires that you are using. Refer to the table on the left
for quantities of each luminaire that you can connect per PDS-60 device. Refer to the
luminaire product guides for information on electrical configuration for luminaires.
When installing in damp or wet locations, seal all points of possible moisture
ingress with electronics-grade RTV silicone sealant so that water or moisture
cannot enter or accumulate.
Inspect PDS-60 and Accessories
Carefully inspect the box containing the PDS-60 and the contents for any damage.
Assemble Additional Items
The following items are required to mount and connect the PDS-60:
• 3-conductor copper wire for power connections, as required. Luminaire
connections also require 3-conductor copper wire, with the exception of
C-Splash luminaires, which require 4-conductor wire. Standard 3.31 mm
2
(12 AWG) stranded wire is recommended.
• One insulated ring or spade crimp terminal, one 203 mm (8 in) connecting wire
and one wire nut per C-Splash 2 luminaire
• The included three push wire connectors
• CAT 5e or better data cable, as required
• The included black magnetic EMI suppression core (for the power cable)
• The included two white magnetic EMI suppression cores (for luminaire leader
cables)
• Power screwdriver (for mounting)
• Four screws suitable for the mounting surface
• Phillips screwdriver
• An 8 mm hex wrench or adjustable wrench
• The included four 1/2 and 3/4 NPT sealing plugs and rings
• Electronics-grade RTV silicone for installations in damp and wet locations
• Cable strain relief and other connectors as needed (water tight, if required)
• Wire strippers and other tools as needed
Typical Ethernet Installation
Included in the box
PDS-60 power/data supply
(2) White clamp-on EMI suppression cores
Black clamp-on EMI suppression core
(2) Spare fuses
(4) Sealing plugs and rings 1/2 NPT
(4) Sealing plugs and rings 3/4 NPT
(3) Wire connectors
Compatible Luminaires
Ethernet
Switch
Light
System
Manager
PC
PDS-60 24 V
DMX/Ethernet
ColorBlast 12
Power/
Data Supply
Power/
Data Supply
Controller
100 m (328 ft) Max
Controller
305 m (1,000 ft) Max
Ethernet maximum data run length
Luminaire
Max. Quantity Per PDS-60 24 V
ColorBlast 6
2
ColorBlast 12
1
ColorBurst 6
2
C-Splash 2
2