background image

PDS-60  Product 

Guide

4

Installation

PDS-60 is a power/data supply designed for indoor and outdoor DMX and Ethernet lighting 

installations. PDS-60 supplies power and data to low-voltage luminaires from Philips Color 

Kinetics and delivers 62 watts of low-voltage output via two ports. It features a NEMA 4 

(IP66) enclosure, allowing for installation in dry, damp, and wet locations. It automatically 

accommodates input voltages ranging from 100 VAC to 240 VAC.

Owner/User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and user to install, 

maintain, and operate PDS-60 in such a manner as to comply with all applicable codes, 

state and local laws, ordinances, and regulations. Consult with the appropriate electrical 

inspector to ensure compliance.

Plan the Installation

To streamline installation and ensure accurate configuration, start with a layout or 

lighting design plan that shows the physical layout of the installation and identifies 

the locations of all lighting luminaires, power/data supplies, controllers, switches, and 

cables.

DMX and Ethernet Configurations

PDS-60 DMX/Ethernet can be used in either DMX or Ethernet networks. PDS-60  

Pre-Programmed versions can be used only in DMX environments and cannot receive 

incoming signals from controllers. However, they can connect to DMX power/data supplies 

and connected luminaires via their DMX OUT ports.   
DMX is appropriate for relatively simple installations, or for installations in which 

groups of lights operate in unison (for example, for accent lighting, perimeter lighting, 

or cove lighting applications). Typical DMX installations with luminaires from Philips 

Color Kinetics use a controller such as iPlayer 3, a Controller Keypad for turning 

lights on and off and triggering light shows, and one or more PDS-60 devices. PDS-60 

devices can be connected in series to deliver DMX data from a single controller to all 

connected lights. Note that the maximum for DMX data run lengths is 305 m (1,000 ft). 

Because it is not subject to the DMX addressing limitations, Ethernet is the preferred 

environment for large-scale, color-changing light shows and video displays, both of 

which require large numbers of unique addresses. 
Typical Ethernet installations with LED lighting luminaires from Philips Color Kinetics use 

an Ethernet switch, an Ethernet controller (such as ColorDial Pro, Light System Manager, 

or Video System Manager Pro), one or more Ethernet Controller Keypads (for light show 

triggering), and one or more PDS-60 devices. For additional devices in a network, use 

additional Ethernet switch ports. 
In an Ethernet environment, each Philips Color Kinetics power/data supply has a unique 

IP address. Each luminaire connected to the device is automatically assigned  unique 

identifiers that controllers use to identify and manage each luminaire.

E

 

Refer to the PDS-60 Installation 

Instructions for specific warning and caution 

statements.

Typical DMX Installation

iPlayer 3

Controller

PDS-60 24 V 

DMX/Ethernet

ColorBlast 12

PDS-60 24 V 

Pre-programmed

(master unit)

ColorBlast 12

PDS-60 24 V 

DMX/Ethernet

(all other units)

Typical Pre-Programmed Installation

Power/ 

Data Supply

Power/ 

Data Supply

Controller

100 m (328 ft) Max

Controller

305 m (1,000 ft) Max

DMX maximum data run length

Содержание PDS-60 24 V DMX/Ethernet

Страница 1: ...PDS 60 Versatile power data supply for indoor and outdoor applications ...

Страница 2: ...es A downstream power data supply does not have to be a PDS 60 but can be any DMX based power data supply Instead of attaching luminaires to a Pre Programmed PDS 60 you could opt to use it as an outdoor rated light show controller for downstream power data supplies and luminaires PDS 60 24 V Pre programmed is a versatile power data supply designed for indoor and outdoor LED lighting installations ...

Страница 3: ...iNET compatible third party Ethernet controllers PDS 60 Pre Programmed Internal Data Input RJ 45 input and output connectors PDS 60 DMX Ethernet only Data Output RJ 45 3 pin terminal block PDS 60 DMX Ethernet only Power Input Line neutral ground cable flying leads Power Output 2 pin spring terminal Physical Dimensions Height x Width x Depth 91 x 140 x 224 mm 3 6 x 5 5 x 8 8 in Weight 2 kg 4 5 lb H...

Страница 4: ...or accent lighting perimeter lighting or cove lighting applications Typical DMX installations with luminaires from Philips Color Kinetics use a controller such as iPlayer 3 a Controller Keypad for turning lights on and off and triggering light shows and one or more PDS 60 devices PDS 60 devices can be connected in series to deliver DMX data from a single controller to all connected lights Note tha...

Страница 5: ...ded One insulated ring or spade crimp terminal one 203 mm 8 in connecting wire and one wire nut per C Splash 2 luminaire The included three push wire connectors CAT 5e or better data cable as required The included black magnetic EMI suppression core for the power cable The included two white magnetic EMI suppression cores for luminaire leader cables Power screwdriver for mounting Four screws suita...

Страница 6: ... black suppression core to the power cable Near the end of the cable that connects to the power data supply coil the power cable into a small loop Place the section of the loop where the cord is doubled into the suppression core Be sure the cord is securely in the core s middle Snap the core shut around the doubled cord 2 Attach a white suppression core to the luminaire strand or leader cable atta...

Страница 7: ...th the DMX and Ethernet input ports When valid data is detected PDS 60 automatically switches to the appropriate mode The PDS 60 Pre Programmed cannot receive input from controllers but it can pass light show data to downstream DMX devices using its DMX OUT port DMX 1 Using an RJ45 connector cable connect your controller s DMX output port to the DMX IN port on the PDS 60 not applicable for pre pro...

Страница 8: ...X ETHERNET IN DMX OUT R W B W R R W B B R W B W R R W B B Ground z ColorBurst 6 ColorBlast 6 ColorBlast 12 C Splash 2 R W B R W B R W B R W B R W B DMX ETHERNET IN DMX OUT 1 2 3 O S M DMX ETHERNET IN DMX OUT R W B ColorBurst 6 C Splash 2 ColorBlast 6 DMX ETHERNET IN DMX OUT R W B DMX ETHERNET IN DMX OUT R W B W R R W B B R W B W R R W B B Ground z ColorBurst 6 ColorBlast 6 ColorBlast 12 C Splash 2...

Страница 9: ...ctors 1 Install a cable strain relief connector in one of the device s 3 4 in openings in the power connection chamber If necessary use conduit as required by local electrical codes 2 Run the mains voltage power cable through the opening Pull at least 152 mm 6 in of wire into the chamber 3 Strip at least 10 mm 0 38 in of insulation from the wires Join the mains line wire with the flying leads usin...

Страница 10: ... Button Options Button 1 Rainbow Produces a smooth transition through the color spectrum Colors appear to follow each other from luminaire to luminaire Cycles through four effect speed settings Cycles through four width settings then reverses direction and decreases widths 2 Random Produces a sequence of randomly generated solid colors simultaneously on all fixtures Toggles between immediate and fa...

Страница 11: ... way you would address luminaires in an ordinary DMX network For complete details on addressing and on using QuickPlay Pro refer to the Addressing and Configuration Guide available at www colorkinetics com support addressing Status Indicators Each PDS 60 has between two and five status indicators depending on the version of the device All indicators are located inside the luminaire s housing Power...

Страница 12: ... Remove the blown fuse from its metal clips next to the luminaire and data connection ports see image below 4 Replace the fuse with a new 4 A 5 x 20 fast blow fuse 5 Replace the cover ensuring that the gasket is seated properly and that no wires are pinched 6 Attach the cover with the six included screws Tighten screws to 8 to 10 in lbs 1 in lb 11 2985 N cm If you are installing in a wet or damp l...

Отзывы: