Installation & Operation Guide
eS21 LED Raceway
6
eS21 LED RACEWAY SYSTEM OVERVIEW
4. Connecting to the DMX512 Network
Connecting DMX512
Basic DMX512 installation consists of Connecting eS21 LED Raceways together in "daisy-chain" fashion. A cable
runs from the control console to the "DMX IN" connector on the first eS21 LED Raceway . Another cable runs from
the "DMX OUT" connector on the first unit to the "DMX IN" connector on the second LED Raceway. All units are
connected together in this fashion. Do not exceed DMX512 cable length, number of maximum receivers, or
termination rules.
Terminating DMX512
If a unit has cable plugged into its "DMX OUT" connector which runs to another eS21 LED Raceway or other
DMX512 device, a DMX512 terminator is not required on the LED Raceway.
If a unit does not have a cable plugged into its "DMX OUT" connector, the LED Raceway must be terminated by a
five-pin DMX512 termination plug (Strand Lighting part number 71346 or equivalent).
Note:
For more information on DMX512 networking and systems, refer to
"Additional Resources for DMX512" on
page 1
.
Connector
Wire
Conductor
"X" or "A"
Brown
L1
"Y" or "B"
Black
L2
"Z" or "C"
Gray
L3
"W" or "N"
Blue
Neutral
"G"
Green/Yellow
Earth (Ground)
DMX512
DMX512
(out from first to second strip)
DMX512
(out to the next raceway or
DMX512 controlled device*)
Note: * If there are no other DMX512 devices
connected to the LED Raceway, then the LED
Raceway must be terminated (see "
Terminating
DMX512
").
eS21 LED Raceway
DMX512 Connections
DMX512 Signal
XLR Pin Number
Common (Drain)
1
DMX512 -
2
3
No Connection
4
No Connection
5
(from console)
eS21 LED Raceway
DMX512 Termination Plug
120 Ohm