      2

PAN08 can not control the speed of motor.

3. It may have some distance error caused by motor start up time.

4. If user found the error become significant, you may using S1 or S2 move 

shutter to the end or remote move shutter to 0% and 100%, and that will 

automatically calibrate this error.

3-3.4 

MULTILEVEL SWITCH STOP LEVEL CHANGE:

When receive Multilevel Switch Stop Level change Command PAN08 will stop the 

motor.

4  SCENE ACTIVATION COMMAND CLASS

4-1 Scene Activation Set Command

 

When PAN08 receive Scene Activation Set command, it will read the level of the pre-

configured Scene ID from EEPROM. And it will be controlled as a Multilevel Switch 

Set command that described in 3-1. The Dimming Duration of the command will be 

ignored because PAN08 can not control the speed of motor.

5  SCENE ACTUATOR CONFIGURATION COMMAND CLASS

5-1 Scene Actuator Configuration Set Command

[Command Class Scene Actuator Configuration, Scene Actuator Configuration 

Set, Scene ID=1~255, Override bit=0, Level=0~99 or 255]                      The current

setting of PAN08 will not be override.

[Command Class Scene Actuator Configuration, Scene Actuator Configuration 

Set, Scene ID=1~255, Override bit=1, Level=0~99 or 255]                     The Level 

value in this Command is associated to the Scene ID.

5-2 Scene Actuator Configuration G

et Command

[Command Class Scene Actuator Configuration, Scene Actuator Configuration 

Get, Scene ID=1~255 ] 

[Command Class Scene Actuator Configuration, Scene Actuator Configuration 

Report, Scene ID=1~255, Level=0~99 or 255, Dimming Duration=0~0xFE]   Report

the Pre-configured Scene ID of PAN08. 

6

Z-wave’s Groups introduction (Association Command Class Version 2 )

There is only one group called Group1

there is only one node for Group1 which 

support MULTILEVEL_SWITCH_REPORT

METER_REPORT_COMMAND_V3

 

ALARM_REPORT. 

6-1 Report the shutter position 

Every time when user press S1 or S2 and let shutter to move, PAN08 will report the 

position status to controller, and at the moving process when change over 10%  

PAN08 will send Multilevel Switch Report to Group 1 as well.

Multilevel Switch Report

Ex. Report position at 30% 

[Command Class Multilevel Switch

 Multilevel Switch Report

Value = 30(%)]

7

Содержание PAN08-1A

Страница 1: ...er Shutter This in wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 And when manual controlled by push button the controller also can memorize the position and send the new shutter position to its controller ex IP Gateway Adding to Z...

Страница 2: ...ontroller into exclusion mode by following the instructions provided by the controller manufacturer One press one flash LED 2 Pressing Include button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off En ter auto inclusion Reset 1 Pressing Include button three times within 2 seconds will enter inclusion mode Use this procedure only in the event th...

Страница 3: ...n learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the PAN08 is disabled and LED flashes on and off alternately at 0 2 second intervals PAN08 will send alarm_type 8 alarm_Level 0xFF to Group1 Overload state can be cleared by disconnect and reconnect the PAN08 to the main power Choosing a Suitable Location 1 Do not locate th...

Страница 4: ...ter simply press the external switch S1 or S2 The detail is described in 7 5 8 PAN08 built in meter function and can read the Watt KWh V Voltage I Current PF Power Factor of the load by using Z Wave command class user can set a threshold current to get the warning caused by abnormal operation 9 PAN08 have overload protection function and can help to prevent short circuit caused by load Programming...

Страница 5: ... Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOT TOM Command Class Binary Switch Binary Switch Report Value 0xFE UN KNOWN Command Class Binary Switch Binary Switch Report Value 0xFF TOP 2 2 BINARY_SWITCH_SET PAN08 can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top 0xFF...

Страница 6: ...Command Command Class Multilevel Switch Multilevel Switch Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Report Value 0x01 0x62 Between BOTTOM and TOP Command Class Multilevel Switch Multilevel Switch Report Value 0x63 0xFF TOP 3 3 MULTILEVEL SWITCH START LEVEL CHANGE This is the command which user can move the shutter up to the top or down to the bottom Command Class M...

Страница 7: ...de bit 0 Level 0 99 or 255 The current setting of PAN08 will not be override Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 The Level value in this Command is associated to the Scene ID 5 2 Scene Actuator Configuration Get Command Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 C...

Страница 8: ...Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 6 2 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 ...

Страница 9: ...current Meter Value 1 256 Meter Value 2 2 89 A 6 2 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 ...

Страница 10: ...erload Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal When in Two Push Button switch type S1 or S2 are closed and not released to open and PAN08 receive any control moving command from Z Wave RF it will report alarm to Group1 Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0xFF S1 or S2 close to L Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0...

Страница 11: ...lue is 1KWh and default value is 10000 kWh 7 5 External switch type 7 5 1 One Push Button When the configuration setting is One Push Button only S1 input will be valid The control moving commands can be accepted in this switch type while the shutter is moving In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 just like the operation of inclu...

Страница 12: ... S2 7 6 Level Report mode Mode 1 In 5 seconds period after controlled by a moving command it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received request command Mode 2 Whenever the shutter move pass a 10 percent level it will auto report the level to Group 1 node 8 Command Classes The Switch suppor...

Страница 13: ... this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this...

Страница 14: ... connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly a...

Отзывы: