background image

type

6

Level 

report 

mode

1

1-2

2

1:

Report destination 

level in 5s

2:

Report 10 percent 

level while running

7-1 Watt Meter Report Period:

If the setting is configured for 1hour (set value =720), the PAN08 will report its instant

power consumption every 1 hour to the node of Group 1. The maximum interval to 

report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default 

value is 1 hour.

7-2 KWH Meter Report Period:

      If   the   setting   is   configured   for   1hour   (set   value   =6),   the   PAN08   will   report   its

Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond

Group. The maximum interval to report its Accumulated Power Consumption (KW/h)

is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour.

7-3 Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the

setting value is 500, when the load current of Relay1 over this value, PAN08

will send current meter report to warn the Group1 node, the Range of the setting

value is from 10 to 500, and the default value is 500.

7-4 Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting

value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over

this value, PAN08 will send KWh Meter Report command to the node of correspond 

Group, minimum value is 1KWh and default value is 10000 kWh

7-5 External switch type

7-5-1 One Push Button

 

When the configuration setting is One Push Button, only S1 input will be valid. 

The control moving commands can be accepted in this switch type while the 

shutter is moving. In this switch type, the inclusion/exclusion/reset/association 

function can also be fulfilled by pressing S1 just like the operation of include 

button.

  When S1 is short pressed, the shutter will move up toward TOP(0xFF). While in 

this moving S1 is short pressed again, the shutter will stop moving. A third short 

pressing of S1 will move the shutter down toward BOTTOM(0x00). While in this 

moving S1 is short pressed again, the shutter will stop moving. And so on… 

Inverting direction and stopping.

7-5-2 Two Push Button

 (The default setting is Two Push Button (2))

If this setting is configured as Two Push Button, S1 and S2 input will be valid, but

will not accept pressing S1and S2 at the same time. In this switch type, the 

inclusion/exclusion/reset/association function can also be fulfilled by pressing S1

or S2 just like the operation of include button.

When S1 is pressed and hold more than 1.5 seconds, the shutter will move up 

toward TOP(0xFF), and the shutter will stop moving when S1 is released. When 

S2 is pressed and hold more than 1.5 seconds, the shutter will move down 

toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.    

  When S1 is short pressed, the shutter will move up toward TOP(0xFF).  While in 

this moving short pressed S1 again, the shutter just keep moving up toward 

11

Содержание PAN08-1A

Страница 1: ...er Shutter This in wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 And when manual controlled by push button the controller also can memorize the position and send the new shutter position to its controller ex IP Gateway Adding to Z...

Страница 2: ...ontroller into exclusion mode by following the instructions provided by the controller manufacturer One press one flash LED 2 Pressing Include button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off En ter auto inclusion Reset 1 Pressing Include button three times within 2 seconds will enter inclusion mode Use this procedure only in the event th...

Страница 3: ...n learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the PAN08 is disabled and LED flashes on and off alternately at 0 2 second intervals PAN08 will send alarm_type 8 alarm_Level 0xFF to Group1 Overload state can be cleared by disconnect and reconnect the PAN08 to the main power Choosing a Suitable Location 1 Do not locate th...

Страница 4: ...ter simply press the external switch S1 or S2 The detail is described in 7 5 8 PAN08 built in meter function and can read the Watt KWh V Voltage I Current PF Power Factor of the load by using Z Wave command class user can set a threshold current to get the warning caused by abnormal operation 9 PAN08 have overload protection function and can help to prevent short circuit caused by load Programming...

Страница 5: ... Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOT TOM Command Class Binary Switch Binary Switch Report Value 0xFE UN KNOWN Command Class Binary Switch Binary Switch Report Value 0xFF TOP 2 2 BINARY_SWITCH_SET PAN08 can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top 0xFF...

Страница 6: ...Command Command Class Multilevel Switch Multilevel Switch Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Report Value 0x01 0x62 Between BOTTOM and TOP Command Class Multilevel Switch Multilevel Switch Report Value 0x63 0xFF TOP 3 3 MULTILEVEL SWITCH START LEVEL CHANGE This is the command which user can move the shutter up to the top or down to the bottom Command Class M...

Страница 7: ...de bit 0 Level 0 99 or 255 The current setting of PAN08 will not be override Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 The Level value in this Command is associated to the Scene ID 5 2 Scene Actuator Configuration Get Command Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 C...

Страница 8: ...Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 6 2 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 ...

Страница 9: ...current Meter Value 1 256 Meter Value 2 2 89 A 6 2 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 ...

Страница 10: ...erload Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal When in Two Push Button switch type S1 or S2 are closed and not released to open and PAN08 receive any control moving command from Z Wave RF it will report alarm to Group1 Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0xFF S1 or S2 close to L Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0...

Страница 11: ...lue is 1KWh and default value is 10000 kWh 7 5 External switch type 7 5 1 One Push Button When the configuration setting is One Push Button only S1 input will be valid The control moving commands can be accepted in this switch type while the shutter is moving In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 just like the operation of inclu...

Страница 12: ... S2 7 6 Level Report mode Mode 1 In 5 seconds period after controlled by a moving command it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received request command Mode 2 Whenever the shutter move pass a 10 percent level it will auto report the level to Group 1 node 8 Command Classes The Switch suppor...

Страница 13: ... this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this...

Страница 14: ... connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly a...

Отзывы: