16
STOP OF FREEZER OPERATION
The freezer operation can be stopped when removing the frost in the freezer chamber or no use of
freezer.
The current freezer temperature and OFF is displayed alternately when the temperature display indicator
for freezer is lit. (Only the current refrigerator temperature is displayed when the temperature display
indicator for refrigerator is lit. OFF is not displayed.)
Following shows the procedure to stop the freezer operation.
Operation
Key operated
Display after operation
1
Press the temperature display
change over key to display the
freezer temperature.
The temperature display indicator
for freezer is lit and the current
freezer temperature is displayed.
2 Press the set key.
SET
The current setting of freezer (-25)
is displayed and the second figure 2
blinks.
3
Change 2 to 0 by pressing the up
arrow key.
The display changes to -05 from
-25.
Press the scroll key.
The first figure 5 blinks.
Change 5 to 0 by pressing the up
arrow key.
The display changes to -00 from
-05.
4 Press the set key.
SET
The current freezer temperature and
OFF is displayed alternately. (Stop
of freezer operation.)
The setting mode returns to the temperature display mode automatically when 90 seconds has passed
without any key operation (auto-return function). In this case, the setting is not accepted.
<To resume the freezer operation>
Following shows the procedure to resume the freezer operation. The operation is resumed by setting
the freezer temperature.
Example: Setting the freezer temperature to -25
o
C.
•
Following shows an example. Change the setting as necessary.
Operation
Key operated
Display after operation
1
Press the temperature display
change over key to display the
freezer temperature.
The current freezer temperature and
OFF is displayed alternately. (No
freezer operation.)
2 Press the set key.
SET
The setting before stop of operation
(-00) is displayed and the second
figure 0 blinks.
3
Change 0 to 2 by pressing the up
arrow key.
The display changes to -20 from
-00.
Press the scroll key.
The first figure 0 blinks.
Change 0 to 5 by pressing the up
arrow key.
The display changes to -25 from
-20.
4 Press the set key.
SET
The setting is memorized and the
current freezer temperature is
displayed with blink. (Start of freezer
operation.)
The setting mode returns to the temperature display mode automatically when 90 seconds has passed
without any key operation (auto-return function). In this case, the setting is not accepted.
REF.
FREEZ.
REF.
FREEZ.