NewFEIMAS
Refer to Revision Record on page 2.
T.Anzai
Nov. 20, 2008
K.Okada
Rev
04
03
PAGE
103
/
138
PFU LIMITED
P1PA03334-B30X/6
Refer to Revision Record on page 2.
T.Anzai
July 7, 2008
K.Okada
Refer to Revision Record on page 2.
K.Okada
K.Okada
DESCRIPTION
CHECK
DATE
T.Anzai
APPR.
K.Okada
K.Okada
Aug.19, 2005
DESIG
N
DESIG
.
CUST.
I.Fujioka
I.Fujioka
T.Anzai
CHECK
fi-5530C/fi-5530C2
IMAGE SCANNER
MAINTENANCE MANUAL
APPR.
TITLE
DRAW.
No.
Feb.23, 2007
05
Section 5-1-4
(5) When the offset adjustment is terminated abnormally
Screen T35
Function No.
Display
Scanner status
Displays
“c”
without
blinking.
The adjustment has terminated abnormally.
Note: The major reason of abnormal termination is incorrect setting of the test sheet. Set the test sheet correctly and try
the magnification adjustment again.
<Available buttons at Screen T35>
Function
button: Displays error information (Screen T36)
Send to button: Terminates this mode and returns to Screen T04.
Screen T36
Adjustment
mode (*1)
Function No.
Display
Description
0
1,2
Countermeasure when abnormal
termination frequently occurs
1: cannot detect the leading edge of the
document (black detection failed)
√
√
2: cannot detect the left edge of the
document (black detection failed)
√
√
3: cannot detect the leading edge of the
document (white detection failed)
√
√
5: cannot detect the left edge of the
document (white detection failed)
√
√
4: Large skew A
√
√
7: Large skew B
√
√
Conduct necessary operation by
referring to
Section 3-3-6
or
procedure (2) and later in
Section
3-3-9
.
(*1) 0 : ADF front
1,2: ADF back
<Available buttons at screen T36>
Send to button: Terminates this mode and returns to Screen T04.
Skew A and B are calculated by the following expression.
Skew A = a – b
Skew B = c – d
[Test sheet]
Use the same sheet as used for the magnification adjustment. See
Section 5-1-3
, Figure 5-1-3.
a
c
b
d
1
2
5
6
7
4
3