Section 4-10-8
4-10-8. Replacing the BW Motor
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-13
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear cover, Upper cover and Guide A ASSY by
referring to Sections from
4-7-1
to
4-7-6
.
(2) Remove the Dust cover by referring to
Section 4-10-3
.
(3) Remove two motor cables that run on the backside of the
scanner from a hole of chassis and all hooks.
(4) Remove two screws that are fixing the BW motor. Slide
the motor inside and tilt it to remove the motor from the
Upper unit.
Reference: BW motor includes the cable.
<Mounting>
Follow the removing procedure in reverse.
(1) Fix the motor so that the connector of the cable shall be
located in lower side.
(2) When routing the motor cable on backside of the scanner,
insert thinner cable first to avoid cables come out the
hooks.
Cables for motor
Hole of chassis
Screws for BW Motor
BW Motor
The connector of
the cable shall be
lower side.
Cables for motors
Hole of chassis