EN – 14
Accessories
Name
SD
C1
C2
Part number
Location
Fonctions
Oil mist
eliminator
OME 40 S
104887
Exhaust
• Separates oil droplets and particles contained in
exhaust gases emitted by the pump.
OME 40 C1
068785
OME 40 C2
068492
High pressure oil mist
eliminator
OME 40 HP+
200024
Exhaust
• Separates oil droplets and particles contained in
exhaust gases emitted by the pump when pump
operate in high pressure and/or in frequent cycles.
Can be fitted to
ODK 136
and
ODK 236
.
Oil level switch
OLS 36
104377
On oil casing
Provide information about oil level inside oil
casing of RVP, whenever the pump is located in an
unaccessible area.
Oil draining kit
ODK 136
118773
Gas ballast
• Connect to the OME 40 HP+, it is used to
recover oil via the gas ballast.
Note : the pump is not sealed when switched off.
Oil draining kit
ODK 236
118776: 220/240V
50/60 Hz
118777: 115V 60 HZ
Inlet
Connect to the OME 40 HP+, it is used to recover
oil. Equipped with an electrovalve which seals the
pump when switched off.
Sorption trap
ST 40
104731 -115V
053380 220 V
Inlet
• Prevents oil backstreaming when pumping in a
“clean” vacuum.
Automatic gas ballast
AGB 36
068391: 230V 50/60Hz
104367 115V 60Hz
Gas ballast
• Remote control for gas ballast.
• Allows the gas ballast to be closed when the
pump is off, ensuring that the pump is tight.
Oil filter
DE1
068990 220V 50/60Hz
068991 115V 50/60Hz
External device
• Filters and/or neutralizes oil when pumping gases
which are corrosive and could rapidly degrade oil
quality.
Oil filter
DE2
104374 220V 50/60Hz
104375 115V 50/60Hz
Shock mount
082691
LAX 100 model D
Between base
and machine
frame
• Allows pump to be mounted on a frame.
Oil short-circuit
adaptor
054273
On the wessel
pipe fitting
• On C1 model, allows to remove the oil filter
cartridge and replace it by an oil filtration system
type DE1 or DE2.
Possible without restrictions
Possible with restrictions
Out of question
When pumping on corrosive, aggressives or flammable gases, the gas can
cause injury or death. In these cases,
- connect the exhaust of the pump to an exhaust stack or an evacuation
duct.
- connect a relief valve or rupture disc directly on the pump. Contact your
closest service center (see addresses at the back of the manual).
When the exhaust is connected to an extraction duct or an oil mist
eliminator, you must remove the exhaust safety valve mounted in the
pump’s exhaust orifice.
At the pump exhaust, the discharge circuit must be such that the resulting
excess pressure in the oil case is as low as possible. The maximum excess
pressure recommended for correct pump operation is 0.5 bar (6 PSI).
A slight negative pressure in the oil case (0.1 to 0.2 bar / 1.5 PSI), at the
exhaust, will prevent gases from accumulating and reduce pump corrosion
and pollution.
For safety reasons, use accessories on the inlet and exhaust lines whose
materials and sealing properties are compatible with the gases being used.