Adjustment
43
8
880
Starting current main drive
C
1 - 10
8
881
Filter parameter for position controller
C
0 - 12
5
884
Proportional amplification
C
1 - 50
25
of speed control (general)
885
Integral amplification
C
0 - 50
35
of speed control
886
Proportional amplification
C
1 - 50
30
of position controller
887
Differential amplification
C
1 - 50
30
of position controller
889
Time for position control (0 = always)
C
0 - 2550
200
890
Proportional amplification
C
1 - 50
25
of higher ranking speed controller
for standstill brake (rest brake)
891
Proportional amplification
C
1 - 50
20
of subordinate speed controller
for standstill brake (rest brake)
9
901
Cutting release speed
C
180 - 500
400
956
Current for stepping motor axis 2
B
30 - 63
56
957
Current for current reduction
B
15 - 48
39
of stepping motor axis 2
958
Current reduction time
B
0 - 2500
2000
stepping motor axis 2
978
Current reduction time stepping motor 2
C
0 - 99
0
979
Current reduction time stepping motor 1
C
0 - 99
0
985
Position for thread clamp on
B
0 - 127
34
986
Position for thread clamp off
B
0 - 127
103
Group
Parameter
S
et
ting
range
Description
S
et value
User level