Adjustment
30
15
.07.06
Needle thread tension release
Rule
1. The magnet lift should be
1.5 mm
.
2. When the solenoid
5
is operated manually, there should be a clearance of at least
0.5 mm
between the tension discs 6.
O
Turn the disc
1
( nuts
2
) according to
rule 1
.
O
Turn the screw
3
( nut
4
) according to
rule 2
.
Fig. 15 - 23
3
4
5
2
1
0.5 mm
6