Adjustment
13 - 46
13.
07.13
Eccentric sleeve
Requirements
1. In its starting position the scissor must be flush with the contour of the needle plate.
2. The scissor must lightly touch the needle plate and the eccentric sleeve
2
.
Fig. 13 - 42
2
1
3
4
●
Loosen screw
1
enough so that eccentric sleeve
2
can still be turned.
●
Turn eccentric sleeve
2
until the scissor is flush with the needle plate.
●
Maintaining this position move eccentric sleeve
2
laterally in accordance with the
requirement.
●
Tighten screw
1.
●
Press pin
3
( screw
4
) lightly against the scissor.