TANDEM
®
SYSTEM
–
23
#1
#1
#2
#2
ASSEMBLY FOR DOUBLE-SIDED 90 WALL:
END OF WALL
Veneer
F (or G)
Textured ends
Textured end veneer
E
cut at 201 mm
Veneer
E (or F)
END OF DOUBLE-SIDED LAFITT
AND MELVILLE TANDEM WALL
The end of a double-sided Lafitt and Melville Tandem 90 wall is built using a
textured end veneer unit A installed on the end of the wall .
To ensure solid corner assembly, two double-sided connectors are
overlapped in a cross shape and inserted into the mortises on the veneer units .
The first connector connects the two double-sided wall veneer units, while the
perpendicular connector connects the textured end veneer unit that forms
the end of the wall . Glue every course forming the end of the wall using
Permapro adhesive .
The end of a double-sided Lafitt and Melville Tandem 180 wall
is built using a textured end veneer unit E cut at 201 mm
and installed on the end of the wall .
ASSEMBLY FOR DOUBLE-SIDED 180 WALL:
END OF WALL
END OF A DOUBLE-SIDED LAFITT
AND MELVILLE TANDEM 90 AND 180 WALL
The end of a double-sided 90 and 180 wall is built by smoothly combining the
two kinds of construction (90 and 180) for a wall end, described previously in
this document . To build an end for a wall that mixes Tandem 90 and 180
units in the same wall, for each given row height, use units of the same height .
END OF A DOUBLE-SIDED
ESPLANADE TANDEM WALL
The end of a double-sided wall is built using a veneer unit F or G cut at 226 mm
and installed at the end of the wall (see ILLUSTRATION) . For aesthetic reasons,
we recommend having the uncut end of the veneer unit face out .
BUILDING A DOUBLE-SIDED WALL
Connectors in
a cross shape
Plan view
Isometric view
Connectors installed
in a cross shape
Plan view
Elevation view
End of double-sided wall
- side view
Veneer A
Textured ends
226 mm (8 .9")
Textured ends
Double-sided connector
Section to remove
Section to remove
Glue the unit joints
at the ends .
226 mm (8 .9")
Veneer F or G