perma-tec GmbH & Co. KG

- 4 -

The Expert in Lubrication Solutions

SAFETY INSTRUCTION

2.1 

Persons responsible for safety

 

♦  Operator

 

 

▪ 

The operator is any individual or legal entity who or which uses the

 

 

 

lubricator or on whose authority the lubricator is used. 

  

 

The operator or his safety officer must warrant,

 

 

that all the relevant regulations, instructions and laws are adhered to; 

 

 

 

that only qualified personnel will work with and on the lubricator;

 

 

that the operating manual is made available to the personnel 

 

 

 

for all work done with and on the lubricator, and that the personnel    

 

 

 

adhere to it;

 

 

that unauthorized personnel are not allowed to work with and on the  

 

 

 lubricator;

 

 

and that the safety regulations are adhered to when mounting the 

 

 

 

lubricator or during maintenance. 

 

♦  Qualified personnel 

 

 

 

Qualified personnel are persons who, by virtue of their training, experience, 

 

 

instruction and information concerning the relevant standards and provisions, 

 

 

accident prevention regulations and plant and operating conditions, as received  

 

 

from the person responsible for the safety of the plant, are entitled to carry out  

 

 

the activities required at any time so that any possible dangers or hazards can  

 

 

be identified and avoided.  

 

 

 

 

 

 

2.2 

General safety instructions

 

♦  We are not laying claim to completeness as regards these safety instructions.  

 

 

Please contact your local supplier if you have any queries or problems. 

 

♦  At the time of delivery the lubricator is in line with state-of-the-art technology and  

 

 

in principle is considered to be safe to operate.

 

♦  Dangers emanate from the lubricator for persons, the lubricator itself and

  

 

for other material assets of the operator if:

  

 

unqualified personnel operates the lubricator;

  

 

the lubricator is used inappropriately and for operations that it was not

 

 

 

intended to be used for;

  

 

the lubricator setting / variation is incorrect.

Содержание Star Control Time

Страница 1: ...perma STAR CONTROL TIME perma tec GmbH Co KG The Expert in Lubrication Solutions Translation of the Original Operating Instructions perma STAR CONTROL TIME...

Страница 2: ...on can be copied or made available to third parties We have taken great care when compiling all the details contained in this documentation However we cannot rule out discrepancies and we reserve the...

Страница 3: ...s 4 2 3 Safety information for perma STAR CONTROL TIME 5 2 3 1 Safety during installation and maintenance 5 2 3 2 Safety when handling LC units 5 3 TECHNICAL DATA 6 3 1 Data sheet power supply 6 3 1 1...

Страница 4: ...of discharge 14 7 3 1 Examples for determining proper dip switch settings to achieve optimal lubrication 15 7 3 2 Changing the discharge volume after the perma STAR CONTROL TIME has been in operation...

Страница 5: ...ndition 1 1 1 Terms used Lubricator In the following text the lubricator will either be called lubricator or by its name perma STAR CONTROL TIME Lubrication Canister In the following text the Lubricat...

Страница 6: ...system and a label on the LC unit CE Mark on the drive unit Manufacturer perma tec GmbH Co KG Hammelburger Stra e 21 97717 Euerdorf Germany Tel 49 0 9704 609 0 E mail info perma tec com Fax 49 0 9704...

Страница 7: ...n pictures and descriptions perma tec GmbH Co KG can not be held liable for damages and malfunctions caused by inappropriate usage unauthorized alterations to the drive system or the LC unit inappropr...

Страница 8: ...by virtue of their training experience instruction and information concerning the relevant standards and provisions accident prevention regulations and plant and operating conditions as received from...

Страница 9: ...nsure that all workstations and traffic routes are clean and safe Ensure that the relevant regulations and guidelines are adhered to when the installation or maintenance work is carried out in places...

Страница 10: ...to 70 C 23 to 158 F Output load each max 400 mA short circuit proof Cable is drag chain qualified approved for the smallest bending radius 60 mm Power supply 15 to 25 V DC max 30 V DC 5 residual ripp...

Страница 11: ...R1 4 LC unit cannot be refilled c Drive unit consisting of a gear motor and circuit board for control of the lubrica tor Every drive has an individual consecutive series number this number must be pro...

Страница 12: ...of the LC unit With dip switch 1 and 2 marked TIME you can set the discharge amount for every 100 operating hours perma STAR CONTROL TIME divides the set discharge amount size of the LC unit into sev...

Страница 13: ...ed against dust and water jets when the individual parts are assembled correctly Ambient media especially chemically aggressive substances may affect sealing rings and plastic materials 4 STORAGE 4 1...

Страница 14: ...n Completely check the lubricator for visible damages Check if the LC unit is filled with the requested grease or oil Do VOL switches 3 4 of the four way code switch in the drive unit match the correc...

Страница 15: ...t Screw perma STAR CONTROL TIME onto the lubrication point handtight Never screw in the lubricator a second time as this would impair the self sealing of the thread Plug the cable into the connection...

Страница 16: ...nscrew the cover from the drive unit d Remove the drive unit from the LC unit e Dip switches of the 4 way code switch should be changed in cases where a different size LC unit was used or if a differe...

Страница 17: ...it board Dip switches 1 2 marked TIME are used to set the dicharge amount dip switches 3 4 marked VOL are used to set the LC unit size You may set change the switches with the help of a small screw dr...

Страница 18: ...way code switch located on the circuit board of the drive unit If the position of code switches 3 4 VOL of the 4 way code switch does not correspond to the actual size of the LC unit it will lead to...

Страница 19: ...cm3 LC unit S60 Variation II 2 78 cm3 100 h for a 120 cm3 LC unit M120 Variation III 2 89 cm3 100 h for a 250 cm3 LC unit L250 At this point you can calculate the total discharge life of the LC unit...

Страница 20: ...idual lubricant we recommend variation I with a 60 cm3 LC unit Example 2 Given the same machine as in example 1 but with different and irregular running times e g 4 hours on day one 1 5 hours on day t...

Страница 21: ...oon as the motor has run for 2 sec both LED s will light up Pull the plug from the drive unit g Set dip switches TIME and VOL of the 4 way code switch according to chapter 7 3 h Again push and hold th...

Страница 22: ...C unit Partly filled LC unit was replaced by an almost empty LC unit Replace with full LC unit perma STAR CONTROL TIME signals system malfunctions red LED Clogged tube and or connection parts Counter...

Страница 23: ...nge NPT brass plastic part no 26 001 621 Clip plastic part no 26 001 105 Bracket stainless steel part no 26 00012 150 with insert for bracket G1 4o x G1 4i brass part no 26 0011 151 or oil retaining v...

Страница 24: ...a tec GmbH Co KG 20 The Expert in Lubrication Solutions 12 1 Suggestion for PLC connection with one output signal Cable brown STAR CONTROL Cable black Cable white PLC terminal Inputs PLC terminal Outp...

Страница 25: ...perma STAR CONTROL TIME 21 12 2 Suggestion for PLC connection with two output signals STAR CONTROL Cable black Cable white Cable brown PLC terminal Inputs PLC terminal Outputs...

Страница 26: ...tec GmbH Co KG 22 The Expert in Lubrication Solutions 12 3 Suggestion for PLC connection with three output signals STAR CONTROL Cable black Cable white Cable brown PLC terminal Inputs PLC terminal Ou...

Страница 27: ...t Denominaci n producto Nome del prodotto STAR CONTROL TIME Type Type Type Tipo Tipo S60 M120 L250 Produktidenti fikationsnummer Product identifi cation number Num ro d identi fication produit N mero...

Страница 28: ...Co KG The Expert in Lubrication Solutions perma STAR CONTROL TIME perma tec GmbH Co KG Hammelburger Str 21 97717 Euerdorf Germany Tel 49 9704 609 0 Fax 49 9704 609 50 info perma tec com www perma tec...

Отзывы: