perma STAR CONTROL TIME
- 11 -
♦ Pre-lubricate the lubrication point with the same lubricant that is contained in the
perma STAR CONTROL TIME (see chapter 5.1).
♦ Check if the thread of the LC unit corresponds to the thread of the screw
point (R1/4).
♦ In the switch cabinet, connect the cable according to the PLC-wiring diagram for
the status display. The connection may only be carried out by qualified experts
and must be carried out according to local standards (i. e. IEC, VDE etc.).
NOTE: Incorrect connection of the perma STAR CONTROL TIME could
destroy the electronics.
♦ Unscrew and remove the cover of the drive unit. Set the dip switches 1-4
(“TIME” and “VOL”) of the 4-way code switch according to your calculations
(see chapter 7.3). Place cover back on drive unit and remove the plug from the
LC unit. Screw perma STAR CONTROL TIME onto the lubrication point
(handtight). Never screw in the lubricator a second time as this would impair the
self-sealing of the thread. Plug the cable into the connection on perma STAR
CONTROL TIME.
♦ Seal threads of all connecting parts with a suitable, standard sealant. Ensure that
oil filled lubricators are mounted (max. ± 45°) vertically (outlet pointing down).
NOTE: After a reset, perma STAR CONTROL TIME will start with the
corresponding pause time.
5.4
During operation
♦ Carry out regular performance checks during operation.
Check for possible leakages and the status of the lubricator!
♦ Regularly monitor the fill-level of the transparent LC unit!
♦ In case of malfunctions during operation, please check the trouble shooting chart
in chapter 8. If the malfunction cannot be corrected, please contact your perma
distributor.
Please make sure to refer to point 7.3.2 if the settings must be changed after the
perma STAR CONTROL TIME was already put into operation.