perma-tec GmbH & Co. KG
- 14 -
The Expert in Lubrication Solutions
7.2.1
Setting the discharge amount
The lubricant amount per impulse must be set with dip switches 1+2 “TIME” of the
4-way code switch located on the circuit board of the drive unit.
If the position of code switches 1+2 “TIME” of the 4-way code switch does not
correspond to the desired discharge amount (see chapter 7.3), it will lead to wrong
signals and to over- or under-lubrication (see chapter 8).
7.2.2
Setting volume of LC units
The LC unit size must be set with dip switches 3+4 “VOL” of the 4-way code switch
located on the circuit board of the drive unit.
If the position of code switches 3+4 “VOL” of the 4-way code switch does not
correspond to the actual size of the LC unit, it will lead to an incorrect signalling of
fill level (see chapter 8).
7.3
Table of discharge
Amount of discharge in cm
3
(1 cm
3
≈ 0.9 g Lubricant)
per 100 operating hours
Dip switches 1+2
“TIME”
of the
4-way code switch
Code
switch
LC unit
S60
M120
L250
Dip switches 3+4
“VOL”
of the 4-way
code switch
Discharge period
8.33
16.67
34.72
≙
1 Month
at continuous
operation
2.78
5.56
11.57
≙
3 Months
at continuous
operation
1.39
2.78
5.79
≙
6 Months
at continuous
operation
0.69
1.39
2.89
≙
12 Months
at continuous
operation
Time
1 2
Time
1 2
Time
1 2
Time
1 2
Vol.
3 4
Vol.
3 4
Vol.
3 4