26
40, 41
40, 41
40.1
40.1
40.1
B3 Bracing
SB-A0, A, B, C
SB Brace Frame for single-sided walls
Instructions for Assembly and Use – Standard Configuration
Diagonal bracing
– Diagonal bracing is required when
moving and transferring the formwork
unit with the crane.
– Diagonal bracing is in part required
depending on the Brace Frame combi-
nation.
– Values for the individual Brace Frame
combinations depend on height, per-
missible width of influence and fresh
concrete pressure: see PERI Design
Information Brace Frame SB.
– The illustrations are examples only
and show the diagonal bracing re-
quired when transferring Brace
Frames.
– Diagonal bracing is assembled hori-
zontally except for “vertical assem-
bly”.
(Fig. B3.02)
Required components:
40
Scaffold tube Ø 48.3 x 3.2
40.1
Scaffold tube optional
41
Swivel Couplers 48/48 mm
Concreting heights
(Fig. B3.01a - B3.01h)
Assembly
Assembly from bottom to top.
1. Fix horizontal scaffold tubes in the
available couplers.
2. Fix diagonal scaffold tubes to the hori-
zontal scaffold tubes or coupling
tubes with the Swivel Couplers.
3. Depending on the respective width of
influence, optional scaffold tubes can
be left out or have to be mounted dur-
ing concreting and/or moving: see
PERI Design Information Brace Frame
SB.
h = 2.50 – 3.00 m
h = 2.50 – 4.00 m
h = 3.75 – 5.00 m
h = 3.75 – 6.00 m
h = 2.75 – 4.00 m
Fig. B3.01b
Fig. B3.01d
Fig. B3.01e
Fig. B3.01a
Fig. B3.01c
Содержание SB Brace Frame
Страница 2: ......
Страница 6: ......
Страница 29: ...25 SB Brace Frame for single sided walls Instructions for Assembly and Use Standard Configuration ...
Страница 59: ...55 SB Brace Frame for single sided walls Instructions for Assembly and Use Standard Configuration ...
Страница 82: ......
Страница 83: ......