Operation and maintenance manual for the KSP Spark series boilers equipped with feeders. The producer reserves the right to introduce technical modifications.
1. INTRODUCTION
1.1. Obligations of the user and guidelines concerning safety
To assure operational safety and maintain optimum operation
of the equipment:
• read the manual of the boiler and observe their guidelines,
• the manual should be kept and stored in a safe place in
the boiler room allowing using it at any moment of boiler
operation,
• ensure that the equipment is never operated by children
or persons who have not read the contents of the manual
and adults with disabilities preventing them from the safe
operation,
• the system should be made in compliance with the applica-
ble regulations and in accordance with the rules and recom-
mendations contained in the manual.
• before setting and connecting the boiler check whether all
components are in good working order and whether the
boiler has a complete equipment,
• the boiler should be inspected and cleaned at least once a
year and it should include removing a layer of deposited soot
and ash, which reduces the efficiency of the boiler,
• avoid exceeding water temperature in boiler over 95°C,
• maintain operating pressure not exceeding 1.5 bar.
NOTE! Boiler installation in accordance with the applicable
standards and regulations and first start-up should be car-
ried out by a qualified installer.
1.2. Selection of correct power of the boiler
Nominal power of purchased boiler (that is maximum thermal
efficiency, which can be achieved during continuous use and
maintain the efficiency declared by the producer) should be
selected in a way corresponding the real demand for thermal
energy even in case of occurrence of very low temperatures.
Do not purchase boiler with power higher than this planned
in the design. Selecting boiler with too high power will result in
higher fuel consumption and lack of full control over the com-
bustion process and therefore higher operation costs, while too
small boiler will not ensure sufficient power necessary to heat
up the building.
Approximate boiler power can be calculated using a boiler
power calculator on our website
www.pereko.pl
. Furthermore,
you should also consider: thickness of walls and insulation, the
thermal permeability of first fix joinery (including: tightness of
windows and doors, type of window panels used) and climatic
zone, where the heated building is located.