Operation and maintenance manual for the KSP Spark series boilers equipped with feeders. The producer reserves the right to introduce technical modifications.
Diode of local thermostat
The diode is illuminated when local thermostat is connected and it is closed
Diode of chronothermostat
Diode is illuminated if the chronothermostat is active
Diode of igniter
The diode is illuminated when the igniter is supplied
Diode of screw-conveyor feeder
Diode is illuminated when pellet screw-conveyor feeder is operating
Diode of flue gas fan
The diode is illuminated when the flue gas fan is operating
Diode of DHW pump
Diode is illuminated when the DHW pump is operating
Pump ON diode
The diode is illuminated when circulation pump is operating
Alarms diode
The diode is illuminated when the boiler is in alarm condition
4.4.1. Function of controller keys
BUTTON 4
ON/OFF
• Boiler manual switch on and switch off
• Exit from submenu
• Exit from lockout or alarm condition (and switch to switch off condition)
BUTTON 5
POWER DECREASE
• Decrease of set value of power
• Switch from submenu to the previous item
BUTTON 6
POWER INCREASE
• Increase of set value of power
• Switch from submenu to next item
BUTTON 3
MENU SELECTION
• Switch to submenu
• Switch to programming the chronothermostat and clock
• Switch to programming the technical parameters
BUTTON 1
PARAMETERS SETTING
(INCREASE)
• Switch to water temperature in the boiler setting mode
• Increases set value in temperature setting mode
• Increases set value in technical parameters setting mode
• Starts water control in the boiler in work mode
BUTTON 2
PARAMETERS SETTING
(DECREASE)
• Decreases set value in temperature setting mode
• Decreases set value in technical parameters setting mode