Operation and maintenance manual for the KSP Spark series boilers equipped with feeders. The producer reserves the right to introduce technical modifications.
2.2.8. Feeder unit
Feeder unit is driven by the motoreducer and installed inside the
boiler on the left side under yellow panels. Its task is to take the
fuel from the container and feed it automatically to burner part.
Fuel container with cover is installed on the feeder unit.
2.2.9. Flue gas swirlers
Flue gas swirlers are located inside the pipes to swirl flue gas
stream, what has an influence on the increase of efficiency and
the boiler power. Furthermore, they are intended for cleaning of
channels from deposited ash and soot.
2.2.10. Circulation pump, CO
The boiler is equipped with a circulation pump, which is acti-
vated by the local thermostat when temperature 60°C on the
boiler is exceeded.
2.2.11. Equalizing tank
The boiler is equipped with an equalizing tank. Check prelimi-
nary pressure and add increase it if necessary.