Operation and maintenance manual for the KSP Spark series boilers equipped with feeders. The producer reserves the right to introduce technical modifications.
4.4.4. Remote control
Boiler control panel, was also adapted to receive all commands
from the remote control, which is included in the equipment
(Battery type CR2025 3V).
BUTTON 1
• Switch to water temperature in the boiler setting mode
• Increases set value in temperature setting mode
• Increases set value in technical parameters setting mode
• Starts water control in the boiler in work mode
BUTTON 2
• Switch to ambient temperature setting mode
• Decreases set value in temperature setting mode
• Decreases set value in technical parameters setting mode
• Starts ambient temperature control in operation mode
BUTTON 3
• Switch to submenu
• Switch to programming the chronothermostat and clock
• Switch to programming the technical parameters
BUTTON 4
• Boiler manual switch on and switch off
• Exit from submenu
• Exit from lockout or alarm condition (and switch to switch off condition)
BUTTON 5
• Decrease of set value of power
• Switch from submenu to the previous item
BUTTON 6
• Increase of set value of power
• Switch from submenu to next item
4.5. Controller menu
Access to the menu with various items and levels allowing en-
tering to settings and card programming is gained after pressing
the “3” button. Menu items allowing access to the technical pro-
gramming are protected with an access password.
Below review describes briefly menu structure focusing only
on items available for the user.
The following general rules make menu navigation easier:
• Button “3” gives access to the selected menu or submenu,
• Button “4” exits from the current menu or submenu,
• Buttons “1” and “2” changes value of the given parameter
(temperature, hour etc.),
• Buttons “5” and “6” moves between various menu or sub-
menu or between various parameters.
4.5.1. Menu 01 “WATER PRESSURE”
Water pressure in the boiler is displayed in the menu 1. Pressing
“1” and “2” you can also deactivate pressure control (“OFF”) if the
boiler has been connected to open equalizing tank or in case of
pressure transducer failure.