7
Page
Operation and maintenance manual for the KSP Spark series boilers equipped with feeders. The producer reserves the right to introduce technical modifications.
2.4. Operation and technical parameters
L
H
D
P
Parameter
Unit
Boiler model
14
18
22
29
Dimensions
D
[mm]
∅
80
∅
100
L
[mm]
850
H
[mm]
1425
P
[mm]
650
Primary fuel
—
wood pellet
Thermal power range
[kW]
4.2 - 14.4
4.2 - 17.8
5.6 - 21.6
5.6 - 28.8
Temperature of the exhaust gas at power
nominal
[°C]
86
92
106
126
minimum
[°C]
56
56
59
59
Mass flow of the exhaust gas at power
nominal
[g/s]
8.8
10.2
12.8
15.6
minimum
[g/s]
3.6
3.6
4.9
4.9
Water temperature on supply
[°C]
min. 57 / max. 80
Area of heated rooms**
[m²]
do 260
do 320
do 390
do 520
Heated rooms volume
[m³]
do 650
do 800
do 975
do 1300
Charging capacity of container
[kg]
70
Boiler water capacity
[dm³]
100
100
130
130
Heat exchanger material
—
Steel P265GH [PN-EN 10028]
Maximum working pressure
[bar]
1.5 bar
Required min. chimney draught***
[Pa]
20
Supply / Power
[V/W]
230V, 50Hz / 120W
Boiler class acc. to PN-EN 303-5:2012
—
5
Energy class
—
A+
*maximum water temperature in the boiler – 95°C; **for rooms height 2.5 m and insulation with styrofoam 15 cm (q = 55 W/m