3 TECHNICAL SPECIFICATIONS
Power supply ................................................................................... 220±22V AC / 50±1Hz
Turnstile power consumption (without heating system with thermocontrol) ........ max. 20 W
Turnstile operating voltage from external power supply ................................... 12±1.2V DC
Turnstile power consumption from external power supply .................................. max. 15 W
Operating voltage of the heating system with thermocontrol .......................... 24±2.4 V DC
Power consumption of the heating system with thermocontrol ........................... max. 60 W
Turnstile housing overall dimensions (L × W × H) ................................ 280×260×1050 mm
Control unit overall dimensions (L × W × H) ............................................. 270×190×60 mm
Passageway width .................................................................................................. 600 mm
Barrier arm rotation force ................................................................................. max. 3.5 kgf
Turnstile housing control cable
.....................................................................................
3 m
Power cable of the heating system with thermocontrol
................................................. 3 m
Control unit power cable ............................................................................................. 1.5 m
RC panel cable .............................................................................................................. 3 m
Turnstile housing in assembly, net weight ......................................................... max. 37 kg
Control unit, net weight ..................................................................................... max. 3.8 kg
Throughput rate in a free passage mode .................................................... 60 persons/min
Throughput rate in the single passage mode .............................................. 30 persons/min
Mean time to failure ........................................................ no less than 1,500,000 passages
Mean lifetime ................................................................................................... min. 8 years
Electric shock protection class:
Control unit ..................................................... I according to GOST R IEC 335-1-94
Turnstile housing .......................................... III according to GOST R IEC 335-1-94
Ingress Protection Rating:
Control unit ............................................................................. IP40 under EN 60525
Turnstile housing .................................................................... IP42 under EN 60525
Attention!
The CU-02N power supply can be effected either from the AC mains 220V/50 Hz or
from an external DC power supply 12 V via the CU “Bat=12V” connector. External
power supply 12V DC is not included in the standard deliver set and is customer
supply. Power supply unit specifications: 12±1,2V DC, minimum 1.2 A.
Maximum allowable cable length is 30 m
.