or after the passage has been effected (turn of barrier arms. The signal to
“Auto/SYS
”
contact must be transmitted prior to the CU power-up.
To set the passage waiting time from an ACS it is recommended to install a jumper at the
ACS cable header between contacts 5 and 13.
“Ground
”
— the contact connected to the ground connection clip on the CU.
Fig. 3 Control unit connectors
5.4 Unlocking of the turnstile with a mechanical release key
The key (9) of the mechanical lock (10) is intended for unlocking of the turnstile in case of
emergency or power failure (at the AC mains switching off and at complete discharge of
the built-in SPS battery. To unlock the turnstile it is necessary to insert the key (9) into the
lock (10), turn it 90º clockwise and then take out. You can turn the barrier arms freely in
both directions after this.
To block the barrier arms: one of the barrier arms has to take blocking position, after this
turn the key (9) of the lock (10) contra clockwise and take it out of the lock (10).