background image

Assembly and Operation Manual 

10 

The arm rotation sensors, placed inside the turnstile housing, track passages through the 
turnstile. A passage direction is determined according to sequence of sensors actuation. 
The signals are generated at the contacts 

“Sens R/Pass R

 and 

“Sens L/Pass L

 of the 

CU 

“ACS

 connector at each passage when turning the barrier arms. The signal duration 

depends on the rotation speed of the barrier arms. 
There can be 2 variants of signals generation: 

  Variant 1: The high-level signal is transmitted to the 

Sens R/Pass R” contacts at 

passage in one direction (the signal begins at the moment arms are turned 67° and 
ends at the moment the arms are back in their home position), and to the 

“Sens 

L/Pass L

 –  at passage in the opposite direction. 

  Variant 2: Information on state of rotation sensors is transmitted to the 

“Sens 

R/Pass R

 and 

“Sens L/Pass L

 contacts. At passage, turning the hub (11 in Fig.1) 

at 120°, the following pattern is formed:  

 turning at approximately 8° – a high-level signal at 

“Sens R/Pass R

 (the 

transistor is closed); 

 turning at approximately 53° – a high-level signal at 

“Sens L/Pass L

 (the 

transistor is closed); 

 turning at approximately 67° – a low-level signal at 

“Sens R/Pass R

 (the 

transistor is open); 

 turning at approximately 112° – a low-level signal at 

“Sens L/Pass L

 (the 

transistor is open).  

The pattern at the 

“Sens R/Pass R

 and 

“Sens L/Pass L

 contacts is changed at passage 

in the opposite direction. 

 

NOTE! 

The variant of signal generation is set by the jumper on the J3 connector (for the J3 
connector location see label inside the control unit): the jumper is not installed —
variant 1, the jumper is installed — variant 2. At delivery the jumper is not installed. 
The jumper is supplied with a set of spare parts. 

The CU output cascades are the circuit with open collector output with the following signal 
characteristics: 

the maximum voltage ...................................................................... no more than 25 V 
the maximum current.................................................................... no more than 50 mA 

In the initial position the transistors are open (a low-level signal). 
There are several additional signals put out at the CU “ACS” connector: 

Pwr failure”

 – AC mains failure (the open collector, an active high-level signal); 

Pass Sensor”

 – state of additional infrared sensor of an intrusion detector, if 

applied (the open collector, an active high-level signal); 

Bat failure”

 – the SPS failure (the open collector, an active high-level signal); 

Plug-in”

 – the signal informing ACS that the system connector is switched on  

(a low-level signal); 

Auto/SYS”

 – the signal level of this contact determines the way of setting  

the passage waiting time (the signal data is the same as for the 

“RIGHT

“STOP

  

and 

“LEFT

 

contacts):  

 when 

the 

“Auto/SYS

 contact is not connected — the passage waiting time 

is equal to 5 seconds (it is determined by the CU internal program setting); 

  when the low-level voltage is supplied to the contact — the passage waiting 

time is infinite. The turnstile will lock either by a 

“STOP

 signal from an ACS 

Содержание TTR-04CW-24

Страница 1: ......

Страница 2: ...Electromechanical Tripod Turnstile PERCo TTR 04CW 24 Assembly and Operation Manual...

Страница 3: ...he turnstile with a mechanical release key 11 6 MARKING AND PACKAGING 12 7 SAFETY REQUIREMENTS 12 7 1 Installation safety requirements 12 7 2 Operation safety requirements 12 8 INSTALLATION INSTRUCTIO...

Страница 4: ...outlets railway terminals airports etc To ensure fast and convenient passage it is recommended to install one turnstile per 500 people working the same shift or on the basis of maximum working load 30...

Страница 5: ...ontrol unit power cable 1 5 m RC panel cable 3 m Turnstile housing in assembly net weight max 37 kg Control unit net weight max 3 8 kg Throughput rate in a free passage mode 60 persons min Throughput...

Страница 6: ...Plastic plug 4 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 Spare parts Plastic plug 1 Fuses 1 1 250 0 5 2 1 1 250 2 1 ACS connector DBH 15F cable socket 1 H9 connector c...

Страница 7: ...le housing cable 8 AC power cables 9 mechanical release key 10 lock 11 hub 12 cover with LED indication display 13 CU indicators 14 rotation mechanism 15 dowel 16 anchor bolt 10 70 17 screw 4 20 18 fa...

Страница 8: ...an upper part of the turnstile housing there is a rotation mechanism 14 with three barrier arms 2 a locking device a self centering mechanism and arm rotation sensors A LED indication display is locat...

Страница 9: ...housing can be changed by switching the RC panel over to the Wireless connector of the CU Fig 2 The RC panel is equipped with a buzzer for audio signal generation Button push signals from the RC pane...

Страница 10: ...rated from the RC panel from an ACS For connection layout please refer to Fig 8 see Appendix 5 3 1 Control with the remote control panel The following operating modes can be set from the RC panel see...

Страница 11: ...d Sens L Pass L contacts is changed at passage in the opposite direction NOTE The variant of signal generation is set by the jumper on the J3 connector for the J3 connector location see label inside t...

Страница 12: ...s 5 4 Unlocking of the turnstile with a mechanical release key The key 9 of the mechanical lock 10 is intended for unlocking of the turnstile in case of emergency or power failure at the AC mains swit...

Страница 13: ...Manual Warning Use only the serviceable tools for installation Observe general electrical safety rules when laying out the cables All the connectors should be connected up when the CU is switched off...

Страница 14: ...ntrol the vertical position of the turnstile during installation When forming the passage area through the turnstile take into account that the self centering mechanism operates as follows at the barr...

Страница 15: ...Put the plugs 5 in their places 4 If you lay the turnstile cable 7 under the floor surface make a hole for the turnstile cable 7 and for the power supply cable 19 of the heating system with thermocont...

Страница 16: ...TTR 04CW 24 Electromechanical Tripod Turnstile 15 Fig 5 Floor anchor position and cable entries for turnstile housing installation Fig 6 Wall dowel position for the CU installation...

Страница 17: ...e same time the indicators 13 Power and 12V on the CU 3 the pictogram Red cross on the LED indication display 12 of the turnstile housing 1 and the indicator above the STOP button on the RC panel 4 wi...

Страница 18: ...At the battery discharging up to the level of 10 4 V the turnstile turns to the Always closed mode the LED indication display is out the blinking mode of the Battery indicator and of the red indicator...

Страница 19: ...t are on The turnstile is locked in the direction of completed passage 4 Free passage in the set direction open for multiple passages in the permitted direction Press the STOP button and the button co...

Страница 20: ...ower panel The CU Power indicator is on but the 12V indicator is off The RC generates continuous audio signal The 12V 0 5 is burnt out likely due to external short circuit Disconnect the CU from the A...

Страница 21: ...a qualified mechanic who has studies carefully this Manual Prior to the turnstile maintenance works disconnect the CU power supply from the AC mains set up the Power toggle switch to the OFF position...

Страница 22: ...sensors 5 Connect the cable header of the indication board to the control mechanism connector and mount the cover with LED indication display 12 back into its place in the reverse order to the disman...

Страница 23: ...e Q ty Note A1 Control unit CU 02N 1 A2 Remote control panel H 06 4 100 1 A3 Turnstile housing T 04W 24 1 A4 Wireless remote control 1 MSRF 4 A5 Power supply of the turnstile 1 12V 1 2 A6 Power supply...

Страница 24: ......

Страница 25: ...PERCo P O Box 87 Saint Petersburg 194295 Russia Tel 7 812 321 61 72 Fax 7 812 292 36 08 E mail export perco ru support perco ru www perco com...

Страница 26: ...www perco com export perco ru...

Отзывы: