9.4 Actions in emergency cases
For urgent evacuation of people from business facilities in case of fire, natural calamities
and other emergencies, the additional emergency exit should be provided.
To provide unobstructed and fast escape routes in emergency cases through the turnstile,
the key override control can be used. The sequence of actions is described in Clause 6.4.
9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 2.
Table 2 Possible faults and remedy
Fault
Possible cause
Remedy
The turnstile won’t work after its power-up
Light indication on the CU is off
The
“220V/0.5
А
”
fuse is
burnt out
Disconnect the CU from
the AC mains and
replace the fuse on the
CU lower panel
The CU
“Power”
indicator is on but the
“
12V”
indicator is off. The RC generates
continuous audio signal
The
“=12V/0.5
А
”
is burnt
out likely due to external
short circuit
Disconnect the CU
from the AC mains,
clear the circuit and
replace the fuse on the
CU lower panel
At the powering up with the built-in SPS,
the
“Battery”
indicator is blinking
and may switch off
The battery
of the built-in SPS is
discharged
Connect and use the
available external power
supply unit
In the case of the AC mains failure
and the CU operation with the
external/built-in SPS, the turnstile won’t
work, the indicators on the CU are off
The
“=Bat/2
А
”
fuse is
burnt out
Disconnect the CU
from the AC mains
and replace the fuse
on the CU lower panel
All other faults shall be defaulted by the Manufacturer only.
Note:
In case the heating system with thermocontrol is switched off at low temperatures
(lower -5 °
С
), rotation completion time of the barrier arms will increase pro rata
decrease temperature.