TTR-04CW-24 Electromechanical Tripod Turnstile  

Dear customers!

 

We thank You for choosing the turnstile manufactured by PERCo.  

You have purchased a high quality product, which will be long lasting  

in operation provided that installation and operation rules are observed. 

The assembly and operation manual (hereinafter - the Manual) for the 

TTR-04CW-24

 

electromechanical tripod turnstile (hereinafter - the turnstile) contains data that is 
necessary for the most full use of operating advantages of the turnstile as well as chapters 
on packaging, installation and maintenance. 
Only qualified personnel, following the instructions of this Manual, must carry out 
installation and maintenance. 
Abbreviations: 

  ACS – access control system;  

  SPS – standby power supply; 

  CU – control unit; 

  RC panel – remote control panel; 

  WRC – wireless remote control. 

1 APPLICATION 

The turnstile is designed for managing pedestrian flows at entrance points of industrial 
facilities, banks, administrative buildings, retail outlets, railway terminals, airports, etc. 
To ensure fast and convenient passage it is recommended to install one turnstile per 500 
people working the same shift or on the basis of maximum working load 30 persons/min. 

2 OPERATION CONDITIONS 

The 

T-04W-24 

turnstile housing (hereinafter – 

the turnstile housing

) with regard to 

resistance to environmental exposure complies with GOST 15150, category U2 (for an 
outdoor sheltered application or in premises without climate control). This is ensured by 
additional corrosion-resistant zinc coating of the housing and by the built-in heating system 
with thermocontrol. The barrier arms are made of stainless steel as standard. 
Operation of the turnstile housing is allowed at ambient air temperature from -40°

С

 to 

+40°

С

 and at relative air humidity of up to 98% at +25°

С

The CU-02N control unit (hereinafter – the control unit) and remote control panel 
(hereinafter – the RC panel) with regard to resistance to environmental exposure complies 
with GOST 15150, category NF4 (operation in premises with climate control). 
Operation of the control unit and RC panel is allowed at ambient air temperature from 
+1°

С

 to +40°

С

 and at relative air humidity of up to 80% at +25°

С

.  

Содержание TTR-04CW-24

Страница 1: ......

Страница 2: ...Electromechanical Tripod Turnstile PERCo TTR 04CW 24 Assembly and Operation Manual...

Страница 3: ...he turnstile with a mechanical release key 11 6 MARKING AND PACKAGING 12 7 SAFETY REQUIREMENTS 12 7 1 Installation safety requirements 12 7 2 Operation safety requirements 12 8 INSTALLATION INSTRUCTIO...

Страница 4: ...outlets railway terminals airports etc To ensure fast and convenient passage it is recommended to install one turnstile per 500 people working the same shift or on the basis of maximum working load 30...

Страница 5: ...ontrol unit power cable 1 5 m RC panel cable 3 m Turnstile housing in assembly net weight max 37 kg Control unit net weight max 3 8 kg Throughput rate in a free passage mode 60 persons min Throughput...

Страница 6: ...Plastic plug 4 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 Spare parts Plastic plug 1 Fuses 1 1 250 0 5 2 1 1 250 2 1 ACS connector DBH 15F cable socket 1 H9 connector c...

Страница 7: ...le housing cable 8 AC power cables 9 mechanical release key 10 lock 11 hub 12 cover with LED indication display 13 CU indicators 14 rotation mechanism 15 dowel 16 anchor bolt 10 70 17 screw 4 20 18 fa...

Страница 8: ...an upper part of the turnstile housing there is a rotation mechanism 14 with three barrier arms 2 a locking device a self centering mechanism and arm rotation sensors A LED indication display is locat...

Страница 9: ...housing can be changed by switching the RC panel over to the Wireless connector of the CU Fig 2 The RC panel is equipped with a buzzer for audio signal generation Button push signals from the RC pane...

Страница 10: ...rated from the RC panel from an ACS For connection layout please refer to Fig 8 see Appendix 5 3 1 Control with the remote control panel The following operating modes can be set from the RC panel see...

Страница 11: ...d Sens L Pass L contacts is changed at passage in the opposite direction NOTE The variant of signal generation is set by the jumper on the J3 connector for the J3 connector location see label inside t...

Страница 12: ...s 5 4 Unlocking of the turnstile with a mechanical release key The key 9 of the mechanical lock 10 is intended for unlocking of the turnstile in case of emergency or power failure at the AC mains swit...

Страница 13: ...Manual Warning Use only the serviceable tools for installation Observe general electrical safety rules when laying out the cables All the connectors should be connected up when the CU is switched off...

Страница 14: ...ntrol the vertical position of the turnstile during installation When forming the passage area through the turnstile take into account that the self centering mechanism operates as follows at the barr...

Страница 15: ...Put the plugs 5 in their places 4 If you lay the turnstile cable 7 under the floor surface make a hole for the turnstile cable 7 and for the power supply cable 19 of the heating system with thermocont...

Страница 16: ...TTR 04CW 24 Electromechanical Tripod Turnstile 15 Fig 5 Floor anchor position and cable entries for turnstile housing installation Fig 6 Wall dowel position for the CU installation...

Страница 17: ...e same time the indicators 13 Power and 12V on the CU 3 the pictogram Red cross on the LED indication display 12 of the turnstile housing 1 and the indicator above the STOP button on the RC panel 4 wi...

Страница 18: ...At the battery discharging up to the level of 10 4 V the turnstile turns to the Always closed mode the LED indication display is out the blinking mode of the Battery indicator and of the red indicator...

Страница 19: ...t are on The turnstile is locked in the direction of completed passage 4 Free passage in the set direction open for multiple passages in the permitted direction Press the STOP button and the button co...

Страница 20: ...ower panel The CU Power indicator is on but the 12V indicator is off The RC generates continuous audio signal The 12V 0 5 is burnt out likely due to external short circuit Disconnect the CU from the A...

Страница 21: ...a qualified mechanic who has studies carefully this Manual Prior to the turnstile maintenance works disconnect the CU power supply from the AC mains set up the Power toggle switch to the OFF position...

Страница 22: ...sensors 5 Connect the cable header of the indication board to the control mechanism connector and mount the cover with LED indication display 12 back into its place in the reverse order to the disman...

Страница 23: ...e Q ty Note A1 Control unit CU 02N 1 A2 Remote control panel H 06 4 100 1 A3 Turnstile housing T 04W 24 1 A4 Wireless remote control 1 MSRF 4 A5 Power supply of the turnstile 1 12V 1 2 A6 Power supply...

Страница 24: ......

Страница 25: ...PERCo P O Box 87 Saint Petersburg 194295 Russia Tel 7 812 321 61 72 Fax 7 812 292 36 08 E mail export perco ru support perco ru www perco com...

Страница 26: ...www perco com export perco ru...

Отзывы: