VisuNet GXP
Mechanical Installation
Required Components
•
VisuNet GXP prepared for panel mounting (S1 option)
•
Kit for wall mounting (WALL-BRACKET-XX00-3-304-N0), which includes 2 x L-shaped
panel mount brackets (1 left, 1 right), 1 x rectangular stiffener frame, 14 x M5 x 25 socket
head cap screws (torque 1.8 Nm), and 14 x M5 lock nuts (torque 4 Nm)
Required Installation Tools
•
8 mm socket wrench for mounting nuts
•
4 mm hex wrench for panel mount brackets
•
Loctite
®
Threadlocker Blue 243
®
All tools should be torque controlled if a torque is specified.
If the Panel Mount Option (S1) is chosen, you will receive a pre-assembled package consisting
of a DPU, a TCU/PCU, and a PSU.
The kit for panel mounting can be ordered separately. For ordering details, see chapter 4.1.
Panel Mounting the GXP
1. Mount the first L-shaped bracket to the back of the display unit. Use the bracket that has four
extra holes at the bottom.
Note
There are two different mounting brackets
—
they are not identical items.
1
L-shaped bracket with extra holes at the bottom
1
VisuNet GXP
System Installation