VisuNet GXP
Mechanical Installation
2
01
9-
10
3
2
3.3.6
Wall Mount Installation
Figure 3.9
VisuNet GXP system H1 housing installed into AG-XX00 housing with additional WALL-
BRACKET-XX00-3-304-N0 and EXTA2 keyboard inside an -F housing with -G
mounting version (1-Arm for mounting to AG-XX00 housing)
Required Components
•
Pre-assembled VisuNet PC- or RM-GXP panel mounted into AG-XX00-* housing (-H1
housing)
•
Wall bracket adapter for wall mounting installation compatible with AG-XX00-* housing
•
Optional EXTA2-* keyboard/mouse
Required Installation Tools
•
8 mm socket wrench for attaching PE hardware and housing screws
•
Safety gloves
•
Loctite
®
Threadlocker Blue 243
®
Warning!
Proper installation on the wall
It is the installer's responsibility to select a suitable location with sufficient strength to hold the
equipment. It is the installer's responsibility to select the proper screws based on the
installation conditions.
256
450
635
582
8
625
451
VisuNet GXP