Closing the Housing
Closing the AG-XX00 Housing
1. Slowly lift the DPU into an upright position until the bolts touch the inner frame of the housing.
2. Slide the DPU about 8 mm to the right until the display panel bolts line up with the cutout
holes on the inner frame of the housing.
3. Slowly and evenly push both lower corners of the DPU into the housing.
Warning!
Risk of injury
Fingers can be inured when the display is moved backed into the housing.
Wear protective gloves and hold the display panel by the frame when moving it.
Warning!
Risk of cable damage
The cables may become damaged during the closing process.
Properly fasten all cables, place them in a protective tube, and push the tube into the pedestal
before closing the housing.