2
01
9-
10
2
3
VisuNet GXP
Mechanical Installation
Attaching Housing to Pedestal
1. Align the pedestal bolts to the hole pattern on the bottom of the housing by rotating the ped-
estal coupling 90
°
in relation to the cable glands at the bottom of the pedestal.
2. Carefully place the housing face down on an even, cushioned surface.
3. Remove all screws from the back of the housing.
4. Carefully turn the housing so that the display is facing up.
5. Pull on both lower corners of the display bezel until the display extends away from the
housing.
6. Slide the display panel about 8 mm to the left to lock the panel mechanism that secures the
display. This will allow you to open the housing quickly and safely after it has been secured
to the top of the pedestal and will prevent the outer seal from being clamped.
Figure 3.7
Housing prepared for mounting onto pedestal
7.
Using a crane or with the help of another person
, place the housing onto the pedestal
so that the pedestal bolts align with the keyhole slots and the housing rests on the pedestal.
Manually secure the housing the entire time so that the DPU does not fall open.