VisuNet GXP
Mechanical Installation
2
01
9-
10
3
4
3.3.7
Mounting the Keyboard
The EXTA2-* is the system keyboard/mouse available with a mounting option (option -G) for
the VisuNet GXP AG-XX00 housing.
Required Components
•
VisuNet GXP pre-assembled in AG-XX00 housing
•
EXTA2-* keyboard/mouse (screws included)
Required Installation Tools
•
3 mm hex wrench for cover screws
•
4 mm hex wrench for keyboard arm
•
Loctite
®
Threadlocker Blue 243
®
All tools should be torque controlled if a torque is specified.
Mounting the EXTA2-*-G-* Keyboard to Housing AG-XX00
1. Open and remove the four cover plate screws on the bottom-left side of the AG-XX00 hous-
ing.
2. Route the keyboard cable with the protective tube through the hole of the AG-XX00 housing.
3. Using the screws and lock washers delivered with the EXTA2-*-G-* keyboard, attach the
keyboard to the AG-XX00 housing.
4. Fasten the four screws with a torque of 6 Nm.
VisuNet GXP