2
018-
04
88
HART Multiplexer System KFD*-HM*-16
Appendix
PACTware
TM
PACTware
(
PACTware
–
P
rocess
A
utomation
C
onfiguration
T
ool) is
a manufacturer-independent operating software for devices. In the past, it was often necessary
to use multiple manufacturer-specific programs to be able to operate different devices.
PACTware
enables you to operate any number of devices with just this software.
PACTware
is
not only a configuration tool, it also offers an interface to HART-compatible field devices as
well as to bus systems such as PROFIBUS, MODBUS, and ControlNet.
PACTware
offers
many features that allow users to simplify the plant documentation, to create trend curves, and
to monitor signals using HART data.
Point-to-point connection
In point-to-point connections, only two communication participants can be connected to one
segment (core pair). A point-to-point connection is, for example, the master-slave connection
of multiplexer device to field device.
Primary variable
This variable is a process measured value of the field device. The unit differs according to the
HART command (see commands 1, 2 and 3). The primary variable of a pressure transducer
may be, for example, the measured process pressure in
bar
.
Primary master
See Multi master
Secondary variable
This variable is a further, additional process measured value of the field device. Up to 4
additional values are supported via HART. This variable can only be read using
HART command 3.
Secondary master
See Multi master
Slave
A device in a master-slave system that receives commands from a master. A slave cannot
initiate a transmission request.
Smart field device
Intelligent, programmable field device with microprocessor and memory which is able to
perform calculations, integrated diagnostics, and fault reports and can communicate with a
remote control.
Tag
Unique identifier of the C&I point (
C
ontrol and
I
nstrumentation technology) of the field device
within a process plant.
Содержание KFD Series
Страница 1: ...ISO9001 3 HART Multiplexer System KFD HM 16 PROCESS AUTOMATION MANUAL ...
Страница 41: ...HART Multiplexer System KFD HM 16 Configuration 2018 04 41 Figure 6 4 HART communication parameter window ...
Страница 46: ...2018 04 46 HART Multiplexer System KFD HM 16 Configuration Figure 6 7 General window device information ...
Страница 50: ...2018 04 50 HART Multiplexer System KFD HM 16 Configuration Figure 6 10 Command caching window ...
Страница 54: ...2018 04 54 HART Multiplexer System KFD HM 16 Configuration Figure 6 13 HART Scan wizard ...
Страница 55: ...HART Multiplexer System KFD HM 16 Configuration 2018 04 55 Figure 6 14 HART Scan Wizard communication options ...
Страница 66: ...2018 04 66 HART Multiplexer System KFD HM 16 Operation Figure 7 1 Scan loops window ...
Страница 68: ...2018 04 68 HART Multiplexer System KFD HM 16 Operation Figure 7 2 Connected field devices window ...
Страница 89: ...HART Multiplexer System KFD HM 16 Notes 2018 04 89 ...
Страница 90: ...2018 04 90 HART Multiplexer System KFD HM 16 Notes ...
Страница 91: ...HART Multiplexer System KFD HM 16 Notes 2018 04 91 ...