Product Description
20
13-
01
15
4.7
Displays and controls
LEDs
Operating elements
Description
Function
Status description
1
2
Status display for
R/W heads
LED lights up
green
when there is an active
command on the R/W head.
LED lights up
yellow
for approx. 1 second when a
command is executed successfully.
CH1
CH2
Indicates that a
R/W head is
connected
LED lights up
green
when an R/W head is
connected to channel 1 or channel 2.
LED lights up
red
when a configuration error occurs.
PWR/ERR
Status display for
IDENTControl
Compact
LED lights up
green
when the IDENTControl
Compact is connected to a power supply and the
interface is ready for operation.
LED lights up
red
if a hardware fault occurs.
BUS
Status display of
the bus
LED is off until initial communication is made via the
PROFIBUS.
LED lights up
green
when the status of the slave is
Data Exchange
.
LED lights up
red
when a bus fault occurs and
Data
Exchange
is not possible.
Diag
No function
-
Rotary switch
Address setting 00 ... 7E, FF (hexadecimal)
BUS address (high nibble): 0 ... 7, F
BUS address (low nibble): 0 ... F
BUS Address
(High Nibble)
BUS Address
(Low Nibble)
0
8
C
4
F
7
B
3
E
6
A
2
D
5
9
1
0
8
C
4
F
7
B
3
E
6
A
2
D
5
9
1
CH2
CH2
CH1
CH1
1
2
PWR/ERR
BUS
Diag