Commands
20
13-
01
59
The advantage of "default read" operating mode is the readout speed. The
readout of one data word (4 bytes) is twice as fast in this mode as the other
modes. The readout of two words takes approx. 1/3 less time. No more time
advantages can be gained after three data words because "default read" mode is
designed to read a maximum of two words (= 8 bytes). Reading larger data
ranges can lead to error messages if the reading head does not respond within
the planned reaction time.
Setting "Default Read"
1. Activate the password mode.
2. Write the read range start and end into the "Control Word".
3. Deactivate the password mode.
4. Read the data range with address designation 0000h and word count 0h.
Note!
The addresses for the start and end of the read range are based on the absolute
word address of the read/write tag, not on <WordAddr>.
Example: With the setting read range start 03h and read range end 03h, the R/W
head only reads the first data word in the read/write tag.