![Pepperl+Fuchs IC-KP2-2HB6-V15B Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp2-2hb6-v15b/ic-kp2-2hb6-v15b_manual_1527663068.webp)
20
13-
01
68
Commands
Type IDC-...-1K tags can be programmed in such a way that they are compatible
with the type ICC-... read only carriers. This programming occupies the first 8
bytes in the tag. The read/write commands can be used to access the remaining
memory.
You must set the tag type '50' in order to program type IDC-...-1K tags. To do this,
transmit the command
SX
or
EX
.
The value range contains 7 characters:
■
the first 3 characters contain the values 0 ... F (hexadecimal code)
■
the last 4 characters contain the values 0 ... 9 (decimal code)
You must select the tag type '50' (ICC-...) beforehand in order to read out this
code. If a "read only code" command is executed when the tag type '50' (IDC-...-
1K) is set, the 4-byte read only code for this tag is issued.